Enhanced Lung Protective Ventilation for ARDS Patients With PrismaLung (PROVAP)

H

Hôpital Européen Marseille

Status

Terminated

Conditions

Acute Respiratory Distress Syndrome

Treatments

Device: PrismaLung

Study type

Interventional

Funder types

Other

Identifiers

NCT03004885
2016-A01523-48

Details and patient eligibility

About

Acute Respiratory Distress Syndrome (ARDS) still remains associated with a mortality rate of 30 - 45 % despite improvement in mechanical ventilation. Driving pressure, defined as the difference between the end-inspiratory and the end-expiratory airway pressure, appears as an important factor contributing to mortality in patients with the ARDS. In patients already receiving a conventional tidal volume of 6 ml/kg predicted body weight (PBW), a driving pressure ≥ 14 cmH2O increases the risk of death in the hospital. One mean to lower the driving pressure is to decrease the tidal volume such that from 6 to 4 ml/kg predicted body weight. However, this strategy promotes hypercarbia by reducing the alveolar ventilation, providing the respiratory rate is constant. In this setting, implementing an extracorporeal CO2 removal (ECCO2R) therapy may offset the associated hypercarbia. The investigators have previously demonstrated that combining a membrane oxygenator within an hemofiltration circuit provides efficacious low flow ECCO2R on a renal replacement therapy monitor. In this study, we thought to investigate the efficacy of the PrismaLung stand-alone therapy. Using a PrismaFlex monitor and a HP-X circuit, a neonatal membrane oxygenator (PrismaLung) is used to provide decarboxylation without renal replacement therapy. The study will consist in three periods:

  • The first period will address the efficacy of the PrismaLung device at tidal volume of 6 and 4 ml/kg PBW using an off-on-off design.

  • The second part of the study will investigate the effect of varying the sweep gas flow and the mixture of the sweep gas on the CO2 removal rate (random order).

  • The third part will compare three ventilatory strategies applied in a cross-over design :

    1. Minimal distension: Tidal volume 4 ml/kg PBW and positive end-expiratory pressure (PEEP) based on the ARDSNet PEEP/FiO2 table (ARMA).
    2. Maximal recruitment: 4 ml/kg PBW and PEEP adjusted to maintain a plateau pressure between 23 - 25 cmH2O.
    3. Standard: Tidal volume 6 ml/kg and PEEP based on the ARDSNet PEEP/FiO2 table (ARMA).

Each strategies will be apply in a random order for a duration of 22 hours. Pulmonary inflammatory and fibrosis pathway will be assess before and after each period using bronchoalveolar lavage (BAL) samples. Systemic inflammatory cytokines will also be investigate. Main measurements will include respiratory mechanics, transpulmonary pressure, work of breathing, end-expiratory lung volume and tidal ventilation using electrical impedance tomography.

Enrollment

1 patient

Sex

All

Ages

18+ years old

Volunteers

No Healthy Volunteers

Inclusion criteria

  • ARDS moderate or severe (Berlin criteria)
  • Onset < 48 h
  • Driving pressure ≥ 14 cmH2O

Exclusion criteria

  • Lack of consent or social protection
  • Chronic respiratory failure (requiring Oxygen or NIPPV)
  • Severe hypoxemia: PaO2/FIO2 < 100 with PEEP ≥ 18 cmH2O AND FIO2 = 1
  • Acute Renal Failure requiring RRT
  • DNR order or death expected within the next 72 hours
  • Planned surgery or out-of-ICU transportation expected within the next 72 hours
  • Heparin allergy
  • Contraindication to jugular vein catheterization
  • Intracranial Hypertension

Trial design

Primary purpose

Supportive Care

Allocation

Randomized

Interventional model

Crossover Assignment

Masking

None (Open label)

1 participants in 3 patient groups

Minimal Distension
Experimental group
Description:
Tidal volume 4 ml/kg PBW and PEEP based on the ARDSNet PEEP/FiO2 table (ARMA) + ECCO2R
Treatment:
Device: PrismaLung
Maximal Recruitment
Experimental group
Description:
Tidal volume 4 ml/kg PBW and PEEP adjusted to maintain plateau pressure between 23 - 25 cmH2O + ECCO2R
Treatment:
Device: PrismaLung
Standard
Active Comparator group
Description:
Tidal volume 6 ml/kg PBW and PEEP based on the ARDSNet PEEP/FiO2 table (ARMA) without ECCO2R
Treatment:
Device: PrismaLung