Left atrial catheter ablation including pulmonary vein isolation is a standard therapy in the management of symptomatic atrial fibrillation; however thermal esophageal injury is a known potential consequence of this procedure. Delivery of radiofrequency (RF) energy necessary to perform left atrial ablation has the potential to cause injury to the nearby esophagus including ulceration, hematoma, spasm, esophageal motility disorders, and, in the most extreme case, atrial-esophageal fistula (AEF). Esophageal mucosal lesions are the likely precursor to AEF, and esophageal mucosal lesions have been detected on post-ablation endoscopy after pulmonary vein isolation with an incidence ranging from 3% to 60%.
Active esophageal cooling during RF ablation as a means of esophageal injury prevention has been investigated through mathematical models, pre-clinical studies, and in clinical trials. Existing data support the efficacy of this approach, but the practice has not been widely adopted due to lack of a commercially available device.
The aim or purpose of this study is to evaluate the impact on procedural efficiency of ablation procedures performed using esophageal heat transfer to cool the esophagus during left atrial RF ablation.
Full description
This study is a prospective, pilot study using the Attune Medical esophageal heat transfer device to actively cool the esophagus during RF ablation procedures. This design is appropriate to gather the data needed regarding overall procedural time, compare this to historical controls, and estimate a sample size for a larger study powered for statistical significance.
The subjects will undergo preparation and anesthesia procedures following standard practice. Once the patient is intubated, the esophageal heat transfer device will be placed into the esophagus according to the Instructions for Use (IFU). The device will remain in place until the ablation procedure is completed and will be removed before extubation. Posterior left atrial wall ablation using standard parameters will only be performed when the esophageal heat transfer device has reached a temperature of 4-6 degrees C for at least 2 minutes. The device will be set to neutral or warming temperature (37-42 degrees C) during other aspects of the procedure (such as mapping and anterior wall ablations).
All patients will be followed up in total for 6 weeks (Long Term Follow-up visit) after the procedure to document any clinical complication related to thermal esophageal injuries if applicable.