ClinicalTrials.Veeva

Menu

Evaluating Edge-to-edge Transcatheter Tricuspid Valve Repair in Patients With Severe Symptomatic Tricuspid Regurgitation (TRACE-NL)

S

St. Antonius Hospital

Status

Invitation-only

Conditions

Cardiac Catheterization
Heart Failure, Right Sided
Tricuspid Valve Regurgitation, Nonrheumatic
Valve Regurgitation, Tricuspid

Treatments

Device: TriClip TTVr system (Abbott Vascular)
Device: PASCAL TTVr system (Edwards Lifesciences)

Study type

Interventional

Funder types

Other

Identifiers

NCT05628779
NL81645.100.22

Details and patient eligibility

About

This is a national multicenter, open-label, randomized controlled trial to show superiority of edge-to-edge Transcatheter Tricuspid Valve repair (TTVr) on top of the Standard Of Care (SOC; heart failure medication) over the SOC alone in patients with symptomatic severe Tricuspid Regurgitation (TR) in the Netherlands.

Full description

Tricuspid valve regurgitation (TR) is a common heart valve disease associated with mortality, heart failure hospitalization (HHF) and a significant negative impact on quality of life (QoL). The prevalence of moderate or severe TR in the Netherlands is estimated at 0.55% and becoming more prevalent. Surgery is rarely performed, because in-hospital mortality is high and there is little evidence for the efficacy. The majority of patients does therefore entirely dependent on treatment with heart failure medication. However, a subset of these patients experience (progressive) symptoms of refractory congestive heart failure despite the SOC with heart failure medication.

Transcatheter Tricuspid Valve repair (TTVr) offers several new strategies to address severe TR; one promising technique to treat patients with symptomatic severe TR is edge-to-edge tricuspid valve (TV) repair through leaflet approximation. Edge-to-edge TTVr may provide an elegant alternative treatment for many patients, because it is less burdensome due to the minimally invasive nature. Moreover, multiple single-arm trials already reported promising outcomes in terms of efficacy and safety, and the technique is very similar to Transcatheter Mitral Valve repair (TMVr), with yet proven feasibility, efficacy and safety.

The aim of this study is to evaluate the safety, efficacy and cost-effectiveness of TTVr for patients with symptomatic severe TR despite the SOC and high/prohibitive surgical risk in the Netherlands.

Enrollment

150 estimated patients

Sex

All

Ages

18+ years old

Volunteers

No Healthy Volunteers

Inclusion criteria

  1. The patient is symptomatic (New York Heart Association Functional Class II, III or ambulatory class IV) despite Standard Of Care (SOC). The Central Screening Committee (CSC) will assess whether the patient is receiving SOC. The CSC will also ensure that in case of the presence of atrial fibrillation, left sided heart valve disease (not requiring intervention) or coronary artery disease, conditions are first treated adequately with medication and/or (surgical) intervention.
  2. The patient suffers from ≥ grade 3 isolated TR as determined by the assessment of a qualifying transthoracic echocardiogram (TTE) and three-dimensional transesophageal echocardiogram (3DTEE) and confirmed by the CSC, according to European Association for Percutaneous Cardiovascular Interventions (Tricuspid Focus Group) consensus document (in press). Note: If cardiac procedure(s) occur after eligibility was determined, TR grade will be re-assessed 30 days after the procedure.
  3. The cardiac surgeon of the sites' local heart team concurs that the patient is at high estimated risk for mortality or morbidity with TV surgery.
  4. The patient is ≥18 years of age at time of consent.
  5. The patient must provide written informed consent prior to any trial related procedure.

Exclusion criteria

  1. Systolic pulmonary artery pressure (sPAP) > 70 mmHg or fixed pre-capillary pulmonary hypertension as assessed by right heart catheterization. Severe uncontrolled hypertension Systolic Blood Pressure (SBP) ≥ 180 mmHg and/or Diastolic Blood Pressure (DBP) ≥ 110 mmHg.
  2. Any condition that would interfere with a TTVr procedure, such as prior tricuspid valve repair or tricuspid valve leaflet anatomy which may preclude device implantation (e.g. calcification in grasping area, a severe coaptation defect of the tricuspid leaflets (no clip placement possible), pacemaker or Implantable Cardioverter Defibrillator (ICD) leads that would prevent appropriate placement or visualization of TTVr devices, Ebstein Anomaly (normal annulus position, but valve leaflets attached to walls and septum of the right ventricle), tricuspid valve anatomy non evaluable by echo, known allergy or hypersensitivity to dual antiplatelet therapy AND anticoagulant therapy or to device materials, femoral venous mass or thrombus or vegetation.
  3. Indication for left-sided (e.g. severe aortic stenosis, severe mitral regurgitation) or pulmonary valve correction within prior 60 days. Note: concomitant mitral valve disease (e.g. mitral regurgitation) will be treated first and patients will be reassessed for the trial after 60 days.
  4. Tricuspid valve stenosis - Defined as a tricuspid valve orifice of ≤ 1.0 cm2 and/or mean gradient ≥5 mmHg.
  5. Left Ventricular Ejection Fraction (LVEF) ≤20%
  6. Active endocarditis, active rheumatic heart disease, other ongoing infection requiring antibiotic therapy (enrolment possible 30 days after discontinuation of antibiotics with no active infection) or leaflets degenerated from rheumatic disease (i.e. noncompliant, perforated)
  7. Myocardial infarction known unstable angina, or percutaneous coronary intervention within prior 30 days.
  8. Hemodynamic instability defined as systemic systolic pressure <90 mmHg with or without afterload reduction, cardiogenic shock or the need for inotropic support or hemodynamic support device (e.g. intra-aortic balloon pump).
  9. Cerebrovascular Accident (CVA) within prior 90 days
  10. Chronic dialysis
  11. Bleeding disorders or hypercoagulable state, inability to use dual antithrombotic therapy due to contraindication, allergy or hypersensitivity
  12. Active peptic ulcer or active gastrointestinal (GI) bleeding
  13. Life expectancy of less than 12 months
  14. Subject currently participating in another clinical trial (not yet completed primary endpoint) or in another clinical investigation for valvular heart disease.
  15. Pregnant or nursing patients or those who plan pregnancy during the course of the trial. Women of childbearing age are required to have a negative pregnancy test 7 days prior to baseline visit. Women of childbearing age should be instructed to use safe contraception or have a sterilized regular partner.
  16. Presence of anatomic or comorbid conditions, or other medical, social or psychological conditions that, in the eye of the investigator, limits the subject's ability to participate in the clinical investigation or comply with follow-up requirements, or impact the scientific soundness of the investigation results.

Trial design

Primary purpose

Treatment

Allocation

Randomized

Interventional model

Parallel Assignment

Masking

None (Open label)

150 participants in 2 patient groups

Transcatheter Edge-to-Edge Repair (TEER) on top of the Standard Of Care (SOC)
Experimental group
Description:
Transcatheter Edge-to-Edge Repair (TEER) on top of the Standard Of Care (SOC)
Treatment:
Device: PASCAL TTVr system (Edwards Lifesciences)
Device: TriClip TTVr system (Abbott Vascular)
Standard Of Care (SOC)
No Intervention group
Description:
Patients will continue the SOC with heart failure medication following the European Society of Cardiology guideline 2021 recommendations (e.g. diuretics)

Trial contacts and locations

6

Loading...

Central trial contact

Mike Bosschaert, Drs; M.J. Swaans, MD, PhD

Data sourced from clinicaltrials.gov