ClinicalTrials.Veeva

Menu

Evaluating Implant Stability Using Three Devices Osstell®, Periotest® and AnyCheck®

U

University of Baghdad

Status

Completed

Conditions

Edentulous Alveolar Ridge

Treatments

Device: Devices: Osstell®, Periotest® and AnyCheck®.

Study type

Observational

Funder types

Other

Identifiers

Details and patient eligibility

About

A prospective observational study guided by the guidelines of Strengthening The Reporting Of Observational Study in Epidemiology (STROBE) in 2014, that will be conducted to evaluate implant stability using three devices; Osstell®, Peiotest® and AnyCheck® and comparing the results.

Full description

In this study, 40 dental implants will be installed in osteotomy sites for patients with single or multiple missing tooth or teeth based on radiographic findings (CBCT).

The primary stability will be measured immediately after implant installation using three devices :

  1. Osstell : based on resonance frequency analysis (RFA).
  2. Periotest: based on damping effect.
  3. AnyCheck: based on tapping motion. Secondary stability will be measured after 12 weeks using the same devices mentioned above.

Enrollment

16 patients

Sex

All

Ages

18+ years old

Volunteers

Accepts Healthy Volunteers

Inclusion criteria

  1. Healthy patients over 18 years of either gender, having single or multiple missing teeth in the maxilla and/or mandible.
  2. Patient with adequate vertical bone height and width for implant placement based on preoperative radiographic findings (CBCT).
  3. Ability to tolerate conventional surgical and restorative procedures.
  4. Patients who are willing to comply with the study and give their consent.

Exclusion criteria

  1. Active infection or inflammation in the implant zone.
  2. Presence of any uncontrolled systemic diseases.
  3. Patients with a history of radiotherapy to the head and neck.
  4. Any patient requires advanced and complicated surgical techniques such as sinus lift and bone graft.

Trial design

16 participants in 1 patient group

Adult patient with single or multiple missing tooth or teeth requiring dental implants
Description:
Adult patient with single or multiple missing tooth or teeth requiring dental implants, 40 dental implants will be placed in osteotomy sites based on radiographic findings (CBCT), the primary stability will be measured immediately after implant installation and secondary stability will be measured after 12 weeks . Both primary and secondary stability will be measured by three devices: 1. Osstell®: based on Resonance Frequency Analysis (RFA). 2. Periotest®: based on damping effect. 3. AnyCheck®: based on tapping-motion.
Treatment:
Device: Devices: Osstell®, Periotest® and AnyCheck®.

Trial contacts and locations

1

Loading...

Data sourced from clinicaltrials.gov

Clinical trials

Find clinical trialsTrials by location
© Copyright 2025 Veeva Systems