Evaluation of a Novel Head-Mounted Device for Glaucoma Testing: A Proof-of-Concept Study

B

Brennan Eadie

Status

Not yet enrolling

Conditions

Glaucoma

Treatments

Diagnostic Test: Visual Field Testing

Study type

Interventional

Funder types

Other

Identifiers

Details and patient eligibility

About

This proof-of-concept study aims to determine the feasibility and effectiveness of using a custom head-mounted device for visual field testing. The novel head-mounted device, with custom software, will be compared to a conventional visual field test: The Humphrey Visual Field Analyzer. The investigators will include 30 healthy normal patients, 30 glaucoma suspects, 30 patients with moderate glaucoma, and 30 patients with advanced glaucoma (total: 120 patients). Each patient will perform the conventional test and the head-mounted device visual field test during the study visit, with the order (i.e., which device the patient starts with) being randomized. After the two tests, the patient will fill out a questionnaire to gather information regarding patient comfort and satisfaction. This will repeat each week for 5 weeks, for a total of 5 study visits. The results of the tests (sensitivity thresholds) will be compared. The investigators hypothesize that the results of the conventional and head-mounted device will be similar.

Enrollment

120 estimated patients

Sex

All

Ages

18+ years old

Volunteers

Accepts Healthy Volunteers

Inclusion criteria

  • Previous visual field test with Humphrey Field Analyzer indicating normal field, early glaucomatous field damage, moderate glaucomatous field damage, or advanced glaucomatous field damage.
  • Ability to understand and consent to the study.

Exclusion criteria

  • Diagnosis of secondary glaucoma
  • Diagnosis of non-glaucomatous optic neuropathy or other significant ophthalmic diagnosis that could limit vision (ex. age-related macular degeneration)
  • Significant media opacity
  • Previous intraocular surgery other than cataract surgery
  • Anxiety disorder
  • Pregnancy
  • Seizure disorder
  • Cardiac pacemaker or other implantable devices
  • Severe vertigo or balance disturbance
  • Refractive error greater than +4 diopters and less than -6 diopters spherical equivalent
  • Inability to demonstrate competence to make informed decision regarding study participation

Trial design

Primary purpose

Other

Allocation

N/A

Interventional model

Single Group Assignment

Masking

None (Open label)

120 participants in 1 patient group

Single Arm
Experimental group
Description:
Patients will perform visual field testing with the Humphrey Visual Field Analyzer and with the custom head-mounted device.
Treatment:
Diagnostic Test: Visual Field Testing