ClinicalTrials.Veeva

Menu

Evaluation of a Single-lead ECG Patch-based Telemetry System for In-hospital Monitoring

Yonsei University logo

Yonsei University

Status

Not yet enrolling

Conditions

Bradycardia
Atrial Fibrillation
Hospitalization
Telemetry
Patient Monitoring
Supraventricular Tachycardia
Arrhythmias
Ventricular Tachycardia

Treatments

Device: MEMO-Cue-based telemetry monitoring

Study type

Interventional

Funder types

Other

Identifiers

NCT07260721
1-2025-0048

Details and patient eligibility

About

"This investigator-initiated, prospective, single-center clinical study evaluates the performance and clinical utility of a single-lead electrocardiogram (ECG) patch-based telemetry system for hospitalized patients who require in-hospital telemetry ECG monitoring. The system integrates real-time centralized surveillance (MEMO-Cue) with post-hoc analytic review (MEMO-Care) using ECG signals recorded by the MEMO Patch M, aiming to enable timely recognition of clinically important arrhythmias and to inform treatment decisions under routine inpatient conditions.

Adults (≥19 years) indicated for continuous ECG monitoring during admission are enrolled after written informed consent, with a planned sample size of 100 to yield approximately 90 evaluable participants (10% anticipated dropout). The design does not include randomization or blinding. Study procedures include a screening visit (eligibility and baseline data), an inpatient monitoring period of at least 12 hours and up to 8 days with simultaneous MEMO-Cue monitoring and MEMO Patch M recording, and an end-of-visit assessment when MEMO-Care analytic results become available. Concomitant therapies deemed clinically necessary are permitted and documented, and adverse events are prospectively assessed.

Clinical utility endpoints quantify care impact and timeliness: (1) rate of treatment plan changes (e.g., initiation or modification of anticoagulants or antiarrhythmic drugs, cardioversion scheduling, device implantation, or other actions); (2) time to recognition (days) of major arrhythmias-atrial fibrillation (AF), ventricular tachycardia (VT), pause, ventricular premature complex (VPC), and supraventricular tachycardia (SVT)-based on MEMO-Cue alarms or MEMO-Care results with objective confirmation; (3) reduction ratio in recognition time when identified earlier by MEMO-Cue versus MEMO-Care; and (4) proportion of participants with shortened recognition time by MEMO-Cue.

Clinical performance endpoints assess detection characteristics and agreement between MEMO-Cue alarms and MEMO-Care findings: (1) clinical sensitivity (true positive / [true positive + false negative]); (2) precision, i.e., positive predictive value (true positive / [true positive + false positive]); and (3) positive concordance rate (proportion of MEMO-Care-detected arrhythmias alerted by MEMO-Cue). Safety is captured as treatment-emergent adverse events after device application, including device-related skin reactions, detachment, or signal dropouts, with severity graded per NCI-CTCAE v5.0 and relationship to device recorded.

By characterizing real-time patch-based telemetry alongside analytic review and its influence on diagnostic timing and management, the study aims to generate practical evidence supporting feasibility, reliability, and workflow compatibility of single-lead patch telemetry for in-hospital ECG monitoring.

Enrollment

100 estimated patients

Sex

All

Ages

19+ years old

Volunteers

No Healthy Volunteers

Inclusion criteria

  • Adults aged 19 years or older who provide written informed consent for participation.
  • Patients requiring in-hospital telemetry electrocardiogram monitoring during hospitalization.

Exclusion criteria

  • Known hypersensitivity or allergic reaction to adhesives or hydrogel.
  • Presence of skin wounds at the intended application site of the investigational device.
  • Implanted cardiac electronic devices such as pacemakers, ICDs, or other CIEDs
  • Current or past history of skin cancer, rash, dermatologic disorders, keloid formation, or skin injury.
  • Any condition judged by the investigator to increase risk or make participation inappropriate.
  • Cognitive impairment that precludes understanding of study information or voluntary consent.

Trial design

Primary purpose

Diagnostic

Allocation

Non-Randomized

Interventional model

Single Group Assignment

Masking

None (Open label)

100 participants in 1 patient group

MEMO-Cue
Experimental group
Description:
Participants receive continuous in-hospital ECG monitoring using the MEMO-Cue system, which combines a single-lead patch device with real-time telemetry software. Monitoring lasts 12 hours to 8 days, and arrhythmia detection performance is compared with retrospective analysis using MEMO Care.
Treatment:
Device: MEMO-Cue-based telemetry monitoring

Trial contacts and locations

1

Loading...

Data sourced from clinicaltrials.gov

Clinical trials

Find clinical trialsTrials by location
© Copyright 2026 Veeva Systems