ClinicalTrials.Veeva

Menu

Evaluation of Different Methods for Preoxygenation

M

Malin Jonsson Fagerlund

Status

Completed

Conditions

Anesthesia

Treatments

Device: Standard nasal cannula
Device: Humidified high-flow nasal oxygen
Device: Facemask

Study type

Interventional

Funder types

Other

Identifiers

NCT05839665
PreFlow

Details and patient eligibility

About

The goal of this randomised cross-over study is to compare pre-oxygenation using a standard nasal cannula to pre-oxygenation using humidified high-flow nasal oxygen and a tight-fitting facemask in adult volunteers with a BMI below 30 not suffering from pulmonary or cardiac comorbidity.

The main question it aims to answer is:

  • Are there any differences in the effectiveness of pre-oxygenation using a standard nasal cannula compared to using a traditional facemask and pre-oxygenation using humidified high-flow nasal oxygen?

Participants will be pre-oxygenated with 100% oxygen during four minutes intervals. All participants will be pre-oxygenated with various flow rates using a standard nasal cannula, a facemask and humidified high-flow nasal oxygen. End-tidal oxygen concentrations will be measured continuously in order to evaluate the effectiveness of pre-oxygenation.

Each volunteer will be pre-oxygenated repeatedly, with different flow rates, with all three methods of pre-oxygenation and act as its own control.

During facemask pre-oxygenation volunteers will be pre-oxygenated using both tidal volume breathing for four minutes and with eight vital capacity breaths. During pre-oxygenation using the standard nasal cannula flow rates will vary between 15 and 50 l/min. Pre-oxygenation using humidified high-flow nasal oxygen will be performed with flow rates varying between 30 and 50 l/min. Series will be conducted with volunteers breathing with both opened and closed mouth as well as with four minutes of tidal volume breathing and eight vital capacity breaths.

All volunteers will start with facemask pre-oxygenation. They will thereafter be randomised to pre-oxygenation with either a standard nasal cannula or humidified high-flow nasal oxygen. Lastly, they will be pre-oxygenated with the remaining method according to the randomisation.

Full description

Pre-oxygenation before anaesthesia induction is mostly performed using a tight-fitting facemask. Recently, studies have shown that pre-oxygenation using humidified high-flow nasal oxygen is equally effective as pre-oxygenation using a standard tight-fitting facemask. Pre-oxygenation using humidified high-flow nasal oxygen has several potential advantages including improved patient comfort and the possibility of a seamless transition from pre-oxygenation to apnoeic oxygenation. Unfortunately, this technique requires an additional machine which can be expensive and also difficult to use in settings outside a hospital.

In this study, pre-oxygenation using a standard nasal cannula delivering a high flow of oxygen will be compared with standard facemask pre-oxygenation and pre-oxygenation using humidified high-flow nasal oxygen in adult volunteers with a BMI below 30 not suffering from pulmonary or cardiac comorbidity.

The main question it aims to answer is:

  • Are there any differences in the effectiveness of pre-oxygenation using a standard nasal cannula compared to using a traditional facemask and pre-oxygenation using humidified high-flow nasal oxygen?

Participants will be pre-oxygenated with 100% oxygen during four minutes intervals. All participants will be pre-oxygenated with various flow rates using a standard nasal cannula, a facemask and humidified high-flow nasal oxygen. End-tidal oxygen concentrations will be measured continuously in order to evaluate the effectiveness of pre-oxygenation.

Each volunteer will be pre-oxygenated repeatedly, with different flow rates, with all three methods of pre-oxygenation and act as its own control.

During facemask pre-oxygenation volunteers will be pre-oxygenated using both tidal volume breathing for four minutes and with eight vital capacity breaths. During pre-oxygenation using the standard nasal cannula flow rates will vary between 15 and 50 l/min. Pre-oxygenation using humidified high-flow nasal oxygen will be performed with flow rates varying between 30 and 50 l/min. Series will be conducted with volunteers breathing with both opened and closed mouth as well as with four minutes of tidal volume breathing and eight vital capacity breaths.

All volunteers will start with facemask pre-oxygenation. They will thereafter be randomised to pre-oxygenation with either a standard nasal cannula or humidified high-flow nasal oxygen. Lastly, they will be pre-oxygenated with the remaining method according to the randomisation.

Enrollment

20 patients

Sex

All

Ages

25 to 65 years old

Volunteers

Accepts Healthy Volunteers

Inclusion criteria

  • Ability to understand and sign informed consent
  • Age 25-65 years
  • Body mass index <30

Exclusion criteria

  • Heart disease
  • Respiratory disease
  • Pregnancy
  • Smoker

Trial design

Primary purpose

Treatment

Allocation

Randomized

Interventional model

Crossover Assignment

Masking

None (Open label)

20 participants in 3 patient groups

Humidified high-flow oxygen
Active Comparator group
Description:
Humidified high-flow nasal oxygen delivered via the Optiflow device. Repeated series with 100% oxygen with flows varying between 30 to 50 l/min. Volunteers will also be pre-oxygenated with both opened and closed mouth.
Treatment:
Device: Humidified high-flow nasal oxygen
Standard nasal cannula
Experimental group
Description:
Standard nasal cannula connected to an oxygen rotameter Repeated series with 100% oxygen with flows varying between 15 to 50 l/min. Volunteers will also be pre-oxygenated with both opened and closed mouth.
Treatment:
Device: Standard nasal cannula
Facemask
Active Comparator group
Description:
Tight-fitting facemask. Two series will be done where pre-oxygenation will be performed with four minutes of tidal volume breathing and eight vital capacity breaths. This arm is not randomised. All study subjects will start with facemask pre-oxygenation and are thereafter randomised to standard nasal cannula or humidified high-flow nasal cannula.
Treatment:
Device: Facemask

Trial contacts and locations

2

Loading...

Central trial contact

Malin Jonsson Fagerlund, MD, PhD; Albin Sjöblom, MD

Data sourced from clinicaltrials.gov

Clinical trials

Find clinical trialsTrials by location
© Copyright 2026 Veeva Systems