ClinicalTrials.Veeva

Menu

Evaluation of Implant Fixation in Reverse Total Shoulder Arthroplasty

L

Lawson Health Research Institute

Status and phase

Unknown
Phase 3

Conditions

Arthritis

Treatments

Procedure: surgery
Device: 0.8 mm diameter Tantalum marker beads

Study type

Interventional

Funder types

Other

Identifiers

Details and patient eligibility

About

Reverse total shoulder replacement surgery (RTSA) is performed for individuals with advanced arthritis of the shoulder who also have tears in their rotator cuff muscles. A metal hemisphere is placed in the shoulder blade, and a plastic cup on a stem is placed in the upper arm. This orientation is opposite to the normal anatomy, giving rise to the term "reverse" shoulder replacement. While RTSA has a good clinical track record, no studies have examined how well fixed the implanted components are within patients.

Enrollment

40 estimated patients

Sex

All

Ages

50 to 85 years old

Volunteers

No Healthy Volunteers

Inclusion criteria

  • will be any patient with cuff tear arthropathy requiring reverse shoulder arthroplasty.

Exclusion criteria

  • will be any patient with a previous RTSA or TSA (i.e. no revision surgery) or anyone unable to return for RSA imaging (e.g. living >100 km outside of London).

Trial design

Primary purpose

Prevention

Allocation

Randomized

Interventional model

Parallel Assignment

Masking

Single Blind

40 participants in 4 patient groups

pressfit humerus & non-lateralized glenoid
Active Comparator group
Description:
All patients will receive a Delta XTEND reverse shoulder implant (DePuy Synthes, Warsaw, IN). At the time of surgery, 0.8 mm diameter Tantalum marker beads will be injected into the bone surrounding the implant, (n = 6 surrounding the glenoid and n = 6 surrounding the proximal humerus). Half of the patients (n = 20) will be randomized by an opaque envelope intra-operatively to receive a cemented humeral component, and half will be randomized to receive a press-fit (uncemented). Similarly, half of the patients (n = 20) will be randomized by an opaque envelope intra-operatively to receive a lateralized glenoid component, and half will be randomized to receive a non-lateralized glenoid component.Therefore, 4 randomization groups will be created and one of them is -pressfit humerus \& non-lateralized glenoid.
Treatment:
Device: 0.8 mm diameter Tantalum marker beads
Procedure: surgery
pressfit humerus & lateralized glenoid
Active Comparator group
Description:
All patients will receive a Delta XTEND reverse shoulder implant (DePuy Synthes, Warsaw, IN). At the time of surgery, 0.8 mm diameter Tantalum marker beads will be injected into the bone surrounding the implant, (n = 6 surrounding the glenoid and n = 6 surrounding the proximal humerus). Half of the patients (n = 20) will be randomized by an opaque envelope intra-operatively to receive a cemented humeral component, and half will be randomized to receive a press-fit (uncemented). Similarly, half of the patients (n = 20) will be randomized by an opaque envelope intra-operatively to receive a lateralized glenoid component, and half will be randomized to receive a non-lateralized glenoid component.Therefore, 4 randomization groups will be created and one of them is - pressfit humerus \& lateralized glenoid.
Treatment:
Device: 0.8 mm diameter Tantalum marker beads
Procedure: surgery
cemented humerus & non-lateralized glenoid
Active Comparator group
Description:
All patients will receive a Delta XTEND reverse shoulder implant (DePuy Synthes, Warsaw, IN). At the time of surgery, 0.8 mm diameter Tantalum marker beads will be injected into the bone surrounding the implant, (n = 6 surrounding the glenoid and n = 6 surrounding the proximal humerus). Half of the patients (n = 20) will be randomized by an opaque envelope intra-operatively to receive a cemented humeral component, and half will be randomized to receive a press-fit (uncemented).Similarly, half of the patients (n = 20) will be randomized by an opaque envelope intra-operatively to receive a lateralized glenoid component, and half will be randomized to receive a non-lateralized glenoid component. Therefore, 4 randomization groups will be created and one of them is cemented humerus \& non-lateralized glenoid
Treatment:
Device: 0.8 mm diameter Tantalum marker beads
Procedure: surgery
cemented humerus & lateralized glenoid.
Active Comparator group
Description:
All patients will receive a Delta XTEND reverse shoulder implant (DePuy Synthes, Warsaw, IN). At the time of surgery, 0.8 mm diameter Tantalum marker beads will be injected into the bone surrounding the implant, (n = 6 surrounding the glenoid and n = 6 surrounding the proximal humerus). Half of the patients (n = 20) will be randomized by an opaque envelope intra-operatively to receive a cemented humeral component, and half will be randomized to receive a press-fit (uncemented).Similarly, half of the patients (n = 20) will be randomized by an opaque envelope intra-operatively to receive a lateralized glenoid component, and half will be randomized to receive a non-lateralized glenoid component.Therefore, 4 randomization groups will be created and one of them is cemented humerus \& lateralized glenoid.
Treatment:
Device: 0.8 mm diameter Tantalum marker beads
Procedure: surgery

Trial contacts and locations

0

Loading...

Central trial contact

Kate Kelly, M.Sc,MPH/Gero