ClinicalTrials.Veeva

Menu

Evaluation of Length and Quality of Prostate Biopsies Taken by a New Biopsy Needle

R

Region Skane

Status

Enrolling

Conditions

Prostate Cancer (Diagnosis)

Treatments

Device: Novel needle (18 G, 25 cm with 19 mm sample notch) in a new actuator.
Device: Standard Tru Cut biopsy needle (Argon 18G, 25 cm biopsy needle with a 19 mm sample notch) in a standard actuator (Möller Medical Blue RBG-1000-10-1000)

Study type

Interventional

Funder types

Other

Identifiers

NCT04880681
double needle

Details and patient eligibility

About

Patient-blinded randomized controlled trial evaluating length and quality of prostate biopsies taken by a novel biopsy needle.

Full description

Prostate biopsy is the golden standard for prostate cancer diagnosis. Transrectal prostate biopsy (TRUSbx) is the most widely used technique. The biopsy chamber of the Tru Cut needle is in general 19 mm. However, it is on average filled only with 13 mm of tissue. Biopsy length is strongly correlated with diagnostic accuracy of prostate cancer.

Additionally, TRUSbx has a high risk of infection due to bacteria being brought across the colon wall. The investigators have shown that a new needle design reduces this bacterial transfer in an ex vivo setting and a previous trial (NCT049091230) has shown non inferior biopsy length when compared to the standard Tru Cut needle. A further improvement of the needle has now been designed aiming to increase biopsy length and quality, with the possible potential to improve prostate cancer diagnosis. This is the first human pilot aiming to evaluate if biopsy length of the novel needle is superior to a standard Tru Cut biopsy needle in prostate biopsy.

Enrollment

60 estimated patients

Sex

Male

Ages

40+ years old

Volunteers

No Healthy Volunteers

Inclusion criteria

  • Eligible for prostate biopsy
  • Signed informed written consent

Exclusion criteria

  • None (other than general contraindications for prostate biopsy or patient not willing to participate)

Trial design

Primary purpose

Other

Allocation

Randomized

Interventional model

Parallel Assignment

Masking

Double Blind

60 participants in 2 patient groups

Novel needle
Experimental group
Description:
Novel needle (18 G, 25 cm with 19 mm sample notch) in a new actuator.
Treatment:
Device: Novel needle (18 G, 25 cm with 19 mm sample notch) in a new actuator.
Standard Tru Cut needle
Active Comparator group
Description:
Standard tru cut biopsy needle (Argon 18G, 25 cm biopsy needle with a 19 mm sample notch) in a standard actuator (Möller Medical Blue RBG-1000-10-1000).
Treatment:
Device: Standard Tru Cut biopsy needle (Argon 18G, 25 cm biopsy needle with a 19 mm sample notch) in a standard actuator (Möller Medical Blue RBG-1000-10-1000)

Trial contacts and locations

1

Loading...

Central trial contact

Andreas Forsvall; Adam Linder, Ass prof

Data sourced from clinicaltrials.gov

Clinical trials

Find clinical trialsTrials by location