The Institute of Imaged-Guided Surgery (IHU Strasbourg) has two clinical Magnetic Resonance Imaging (MRI) scanners, one with a 3T (3 Teslas) magnetic field used for diagnosis, the other with a magnetic field of 1,5T (1,5 Teslas) used for the interventional (Pre / per / postoperative).
The reference for the visualization of the biliary and pancreatic ducts is a relatively long sequence that needs a breathing-synchronized acquisition leading to artefacts on the images (blur effect).
In order to reduce and/or standardize the acquisition time as well as to limit artefacts, accelerated sequences are developed. Such sequence is available in France recently in the form of WIP Siemens (Work In Progress: sequence in test phase at manufacturer to be marketed in the short or medium term on clinical machines). It incorporates a Compressed Sensing (CS) acquisition scheme allowing the acquisition of a 3D (3 dimensions) sequence similar to the usual sequence by drastically reducing the acquisition time, the sequence CS-SPACE. This sequence exists in two forms:
Full description
The Institute of Imaged-Guided Surgery (IHU Strasbourg) has two clinical MRIs, one with a 3T (Teslas) magnetic field used for diagnosis, the other with a magnetic field of 1,5T (Teslas) used for the interventional (Pre / per / postoperative).
Cholangiopancreatography by MRI (or bili-MRI) accounts for about 25% of MRI examinations at the IHU and is used for the diagnosis of pathologies affecting the bile ducts (lithiasis pathology, cholangitis, tumoral pathology of the bile ducts) and the pancreas (search for a causal pathology to pancreatitis (calculus), ductal pathology, ductal study in tumor pathology). It can be done in preoperative context (cholecystectomy) for research of an associated calculus in the bile ducts, or for an anatomical analysis of the bile ducts (possible anatomical variants ...).
The reference for the visualization of the biliary and pancreatic ducts is a very heavily weighted T2 3D SPACE sequence. A 3D volume is obtained in which they appear in white, and the projection of this volume makes it possible to visualize the entire tract. This sequence is relatively long and needs a breathing-synchronized acquisition. The time of acquisition is then very variable from one patient to another (4 to 8 minutes). This extended acquisition time in addition to the variability of rhythm and respiratory profile can lead to artefacts on the images (blur effect). These are the limits of the respiratory synchronization that triggers acquisition by referring to the position of the liver dome which is not perfectly reproducible from a breathing cycle to the other, potentially degrading the appearance of the bile ducts and the reliability of the diagnosis.
A solution that makes it possible to reduce and / or standardize the acquisition time as well as to limit artefacts is to use an accelerated sequence. Such a sequence is available in France recently in the form of WIP Siemens (Work In Progress: sequence in test phase at manufacturer to be marketed in the short or medium term on clinical machines). It incorporates a Compressed Sensing (CS) acquisition scheme allowing the acquisition of a 3D sequence similar to the usual sequence by drastically reducing the acquisition time, the sequence CS-SPACE. This sequence exists in two forms:
A lot of work is done today in the field of MRI to reduce the time of sequence acquisition. Accelerated acquisition schemes like Compressed Sensing remain marginal but are set to become the norm in the long term. The use of the sequence CS-SPACE at the IHU therefore enters into this perspective of reducing examination times.
The study carried out here on a large number of patients, with two different magnetic fields, applied routinely for diagnosis or anticipation of surgery, could be used by the community of radiologists, hepatogastroenterologists and also digestive surgeons Hepatobiliary.
Enrollment
Sex
Ages
Volunteers
Inclusion criteria
Exclusion criteria
Patient with contraindications to MRI:
Patient presenting, in the judgment of the investigator, an illness that may prevent participation in the procedures provided by the study
Patient who has been operated urgently
Pregnant or lactating patient
Patient in exclusion period (determined by a previous or a current study)
Patient under the protection of justice
Patient under guardianship or trusteeship
Patient subject to a legal protection measure or out of state to express their consent
Patient in a situation of social fragility
A patient may be excluded at the end of the examination if at least one of the three sequences of bili-MRI could not be obtained (apnea impossible, image reconstruction problem).
Primary purpose
Allocation
Interventional model
Masking
53 participants in 2 patient groups