Evaluation of Nucleus 6 Sound Coding Algorithms

Cochlear logo

Cochlear

Status

Completed

Conditions

Hearing Loss

Treatments

Device: Nucleus 6 sound processor

Study type

Interventional

Funder types

Industry

Identifiers

Details and patient eligibility

About

The purpose of the study was to evaluate the features of the Nucleus 6 Sound Processor (CP900 series) on existing Nucleus recipients who currently use the previous generation sound processor, the Cochlear Nucleus CP810 (also commonly known as the Nucleus 5), with a Cochlear Nucleus CI24RE, CI512 or CI422 cochlear implant. The features evaluated included an enhanced Automatic Gain Control (eAGC), the option to provide acoustic amplification in combination with traditional electric stimulation through an acoustic component, and three input processing algorithms: Signal to Noise Ratio - Noise Canceller (SNR-NC), Wind Noise Reduction (WNR) and Automatic Scene Analyzer (SCAN).

As is customary for a single-subject research design, study results will be analyzed for each subject individually. For evaluations where testing took place under two conditions (i.e. Endpoint 2, 3, 4, and 5) a non-inferiority hypothesis test based on the paired comparisons of the % of words correct will be performed. For each subject, the paired difference (P1 minus P2) will be calculated and the mean difference will be tested statistically against a non-inferiority null hypothesis of 10%. Successful rejection of the null hypothesis allows for a conclusion that the performance under the test condition 2 (based on the Nucleus 6 sound processor) will be non-inferior to the test condition 1 (based on the Nucleus 5 sound processor).

Ho: P1 - P2 ≥ 10% Ha: P1 - P2 < 10%

We hypothesize acceptance of the null hypothesis for the Nucleus 6 features.

Testing will be based on a paired t-test with a one-sided 0.05 alpha level. The value of 10% was selected as the non-inferiority margin as one that can be tested with reasonable power and was clinically meaningful.

Enrollment

97 patients

Sex

All

Ages

8+ years old

Volunteers

Accepts Healthy Volunteers

Inclusion criteria

  1. Eight years of age or older
  2. CI24RE, CI500 or CI422 series Nucleus cochlear implant types (commercially approved)
  3. At least 3 months experience with the cochlear implant
  4. Post-linguistic onset of bilateral sensorineural hearing loss, with no congenital component to the hearing loss
  5. Native speaker of English, the language used to assess speech perception performance
  6. Willingness to participate in and to comply with all requirements of the protocol

Exclusion criteria

  1. Unrealistic expectations on the part of the subject, regarding the possible benefits, risks, and limitations that are inherent to the prosthetic device 2. Unwillingness or inability of the candidate to comply with all investigational requirements 3. Additional handicaps that would prevent or restrict participation in the audiological evaluations

Trial design

Primary purpose

Treatment

Allocation

N/A

Interventional model

Single Group Assignment

Masking

None (Open label)

97 participants in 1 patient group

Nucleus 6
Experimental group
Treatment:
Device: Nucleus 6 sound processor

Trial contacts and locations

0