ClinicalTrials.Veeva

Menu

Evaluation of Performance of New IFIS Sleeve

M

Medicel

Status

Not yet enrolling

Conditions

Cataract

Treatments

Device: IFIS sleeve

Study type

Interventional

Funder types

Industry

Identifiers

NCT06067360
IFIS2023

Details and patient eligibility

About

A silicone sleeve will be used on the hydrodissection needle to avoid that the iris can prolaps through the gap between needle and incision wound.

Full description

Cataract surgey is a common operation approximately 25 million pocedures per year worldwide. An essential step of the procedure is hydrodissection where fluid is forced into the eye through a cannula to free the cataract from its capsule. A serious and potential sight threatening complication of hydrodissection is iris prolapse, where the iris comes out of the wound. The overall incidence of iris prolapse during cataract surgery is 0.9% and higher in patients with intraoperative floppy iris syndrome (IFIS) at 11.9% , small pupils and small eyes. Patients on Tamsulosin medication with a Full Set of Project Data IRAS Version 6.3.3 5 DRAFT pupil less than 7.5mm have a 79% risk of prolapse Iris prolapse most often occurs during hydrodissection because the hydrodissection cannula is smaller (approx.1mm) than the wound (2.2-2.7mm) it is introduced through. Therefore the iris can be forced out / prolapse through this gap by the forced injection of fluid.

Traditional methods such as phenylephrine injection into the eye have varying effects can be unlicensed and possibly increase the prolapse risk. Mechanical pupil stretching can permanently damage the iris with complications.

Phacosleeve hydrodissection where the wound is sealed by a phacosleeve and the hydrodissecting irrigation cannula introduced through the sleeve or from side port /incison. The phacosleeve is not designed for this. This study is to use a purpose made tapered sleeve by Medicel in the same fashion as the current phacosleeve.

Enrollment

20 estimated patients

Sex

All

Ages

18+ years old

Volunteers

No Healthy Volunteers

Inclusion criteria

  • patient with planned cataract surgery

Exclusion criteria

  • pregnant woman

Trial design

Primary purpose

Treatment

Allocation

N/A

Interventional model

Single Group Assignment

Masking

None (Open label)

20 participants in 1 patient group

sleeve
Experimental group
Description:
Evaluation of IFIS sleeve performance
Treatment:
Device: IFIS sleeve

Trial contacts and locations

0

Loading...

Data sourced from clinicaltrials.gov