ClinicalTrials.Veeva

Menu

Evaluation of Posturing-Adherence in Patients After Intraocular Surgery

U

University Hospital Tuebingen

Status

Completed

Conditions

Retina; Lesion
Adherence

Treatments

Device: Closure rate of macular holes
Device: Positioning measurement
Procedure: Usefulness of a sketch
Device: Patient feedback

Study type

Interventional

Funder types

Other

Identifiers

NCT02336334
PosturingSensor

Details and patient eligibility

About

Measuring and logging head positions of patients which underwent surgery with gasendotamponades.

Full description

After surgery with gasendotamponades various positions are recommended to support the success of surgery. In patients with macular holes face-down-position is recommended. In patients with retinal detachment the recommended position depends on the region of the detachment.

The adherence of patients to follow this posturing instructions is very inhomogenous. Therefore the investigators want to measure the posturing by the use of a position-sensor. In some study arms the patients also receive a feedback from the sensor (tone, vibration) to correct the position.

The sensor-device was developed by the study-staff and is not commercial available. In addition there is no trade name. The patients safety of the used device was approved by the in house technical department.

Enrollment

48 patients

Sex

All

Ages

18+ years old

Volunteers

No Healthy Volunteers

Inclusion criteria

  • age >18 years
  • full thickness macular hole or retinal detachment
  • informed consent

Exclusion criteria

  • intraoperative complications with the need of other endotamponades
  • combined treatment

Trial design

Primary purpose

Treatment

Allocation

Randomized

Interventional model

Parallel Assignment

Masking

None (Open label)

48 participants in 2 patient groups

With macular hole
Experimental group
Description:
Inclusion of patients with macular holes and randomized allocation to sensor-types and information-types Interventions: Positioning measurement Patient feedback Usefulness of a sketch Closure rate of macular holes
Treatment:
Device: Patient feedback
Device: Positioning measurement
Device: Closure rate of macular holes
Procedure: Usefulness of a sketch
Without macular hole
Experimental group
Description:
Inclusion of patients without macular holes and randomized allocation to sensor-types and information-types Interventions: Positioning measurement Patient feedback Usefulness of a sketch
Treatment:
Device: Patient feedback
Device: Positioning measurement
Procedure: Usefulness of a sketch

Trial contacts and locations

1

Loading...

Data sourced from clinicaltrials.gov

Clinical trials

Find clinical trialsTrials by location
© Copyright 2026 Veeva Systems