ClinicalTrials.Veeva

Menu

Evaluation of Safety and Efficacy of the EndoLift Liver Retractor

Duke University logo

Duke University

Status

Withdrawn

Conditions

Laparoscopic Heller Myotomy
Laparoscopic Sleeve Gastrectomy
Laparoscopic Gastric Banding
Minimally Invasive Surgical Procedure
Laparoscopic Roux-en-Y Gastric Bypass
Laparoscopic Fundoplication Procedure
Laparoscopic Paraesophageal Hernia Repair
Laparoscopic Gastric Resection

Treatments

Device: EndoLift Liver Retractor

Study type

Interventional

Funder types

Other

Identifiers

NCT02008409
Pro00028255

Details and patient eligibility

About

The primary goal of the study is to evaluate the safety of the EndoLift Liver Retractor as an internal laparoscopic liver retraction device. The secondary goals of the study are to evaluate the efficacy of the EndoLift Liver Retractor as an internal laparoscopic liver retraction device and to identify 'best practices' for device utilization.

This study evaluates the use of a specific type of liver retractor (EndoLift). Liver retractors are often necessary during MIS procedures, but this retractor is the only device which is deployed internally (NOT requiring additional skin punctures/incisions for placement of the liver retractor device). All patients undergoing minimally invasive surgery (MIS) at Duke Regional Hospital will be approached.

The new device is expected to have a minimal risk safety profile. The investigators believe that these risks are no more than would be encountered by using any other commercially available retraction device available on the market today. Data will be collected and analyzed by the identified investigators. Continuous variables will be analyzed via T-test and Chi-square analysis will be applied to discontinuous variables. Statistical analysis software such as SPSS® will be utilized when necessary.

Full description

Since the introduction of minimally invasive surgery (MIS) techniques in the 1980's laparoscopic surgery has become the preferred approach for a number of intra-abdominal procedures such as cholecystectomy, gastric bypass, etc.[1] One of the key components of laparoscopic surgery, of any surgery for that matter, is the ability to achieve and maintain adequate visualization of the surgical target throughout the procedure. During certain MIS procedures the patient's internal organs, such as the liver, can block or obscure the surgical view. A number of surgical instruments (retractors) have been developed to help retract abdominal organs "out of the way" during MIS procedures, but all of these devices require an additional abdominal wall puncture/incision to adequately position the device.

Virtual Ports, Ltd. has developed a new laparoscopic liver retractor device, the EndoLift Liver Retractor. This new device does not require additional skin incisions and is placed internally (inside the abdomen) during laparoscopic surgery. The device has 2 ends that "grab" tissue. The body of the device is a smooth, cylindrical steel bar that has minimal risk of traumatizing tissues/organs. The ends of the device are positioned on to peritoneal surfaces (e.g., anterior abdominal wall and/or the right crus of the diaphragm) and the body of the device (smooth cylindrical bar) "pushes" the liver away from the surgical field.

Sex

All

Ages

18+ years old

Volunteers

No Healthy Volunteers

Inclusion criteria

Subjects eligible for this clinical study must fulfill all of the following:

  • Subject is 18 years of age or older.

  • Subject is scheduled for a MIS procedure:

    1. Laparoscopic Gastric Banding
    2. Laparoscopic Roux-en-Y Gastric Bypass
    3. Laparoscopic Sleeve Gastrectomy
    4. Laparoscopic Fundoplication Procedure (Nissen, Toupet, Dor, etc.)
    5. Laparoscopic Heller myotomy
    6. Laparoscopic paraesophageal hernia repair
    7. Laparoscopic gastric resection
  • Subject is able to comprehend and give informed consent for participation in this study.

Exclusion criteria

  • Subjects not eligible for this research study include those that have any of the following:

    • Subject is unable to comprehend and give informed consent for participation in this study.
    • Subject who are pregnant.

Trial design

Primary purpose

Basic Science

Allocation

N/A

Interventional model

Single Group Assignment

Masking

None (Open label)

0 participants in 1 patient group

EndoLift Liver Retractor
Experimental group
Description:
During surgery, the surgeon will use the new internal liver retractor device. The device will retract the subject's liver out of the way and help the surgeon see better during the surgery. The device is placed inside the abdomen during the surgery. It is "clipped" onto 2 safe surfaces inside the abdomen. The device is removed before the surgery ends.
Treatment:
Device: EndoLift Liver Retractor

Trial contacts and locations

1

Loading...

Data sourced from clinicaltrials.gov

Clinical trials

Find clinical trialsTrials by location
© Copyright 2026 Veeva Systems