ClinicalTrials.Veeva

Menu

Evaluation of the Proximal Form of Precontoured Sectional Matrix in Complex Proximal Posterior Restorations (RCT)

Cairo University (CU) logo

Cairo University (CU)

Status

Active, not recruiting

Conditions

Complex Caries

Treatments

Device: Saddle system (TOR VM, Moscow, Russia)
Device: BioFit Posterior Matrix System
Device: Sectional matrix: Classic ring system (TOR VM, Moscow, Russia)

Study type

Interventional

Funder types

Other

Identifiers

NCT07227688
Mona_international_2

Details and patient eligibility

About

Evaluation of the proximal anatomical form quality of different precontoured sectional matrix systems in complex proximal posterior resin composite restorations using Fédération Dentaire Internationale' (FDI) clinical criteria for the evaluation of direct and indirect restorations

Full description

The importance of the interdental anatomy of a class II direct composite restoration is one of the most underestimated topics in direct posterior composite restorations. The proximal emergence profile of the restoration and the contact area should be designed to maximize arch continuity and to minimize food impaction. A thorough knowledge of proper contacts and contours and how they ought to be duplicated as well as predisposing factors for proximal contact loss as proximal caries, embrasure size and position, and marginal ridge location and thickness, all of which contribute to achieving ideal occlusal harmony.

Conventional circumferential matrix systems produced poor proximal contact points with proximal overhangs or open contacts, and they failed to produce optimum contact points; thus, their usage should be prohibited.

It was found that, optimum contact points were highly associated with the sectional matrix system; there was a 70% lower risk for non- optimum contact points than the circumferential matrix system. Open and tight contacts were highly associated with the circumferential matrix system regardless of operator experience. Sectional matrix systems with separation rings should be implemented as the first choice in clinical decision making for proximal posterior restorations.

Although in vitro and in vivo studies showed that the use a contoured sectional metal matrix band with a separation rings results in optimum contact point and emergence profile, its use is technique sensitive due to rounded contours and thin thickness of matrices, which can cause a depression or bending in the matrix material during placement, rendering it unusable. Also, this matrix systems have shortcomings and does not give the expected result in all class II cavities. The variation in depth, width of the box, distance between the cervical cavity margin and the adjacent tooth requires customization of the interproximal space.

As the main objective is to recreate proximal contacts and contour that mimic the natural teeth making this area self-cleansable, preserving the periodontium, improving the restoration durability as well as maintaining the mesio-distal dimension of either dental arch. This mission is more complicated with badly broken-down teeth. By defining a badly destructed tooth we can say that it is a tooth that has lost a significant amount of tooth material which may be due to caries affection, fractures, or even extensive endo treatments. The result is that the remaining tooth structure becomes friable and weakened and presents a challenge during restoration due to increased distance between the cervical cavity margin and the adjacent tooth and the situation is more complicated if part of the buccal and lingual walls are missing making the ordinary sectional matrix liable to collapse after placing the separation rings.

classic ring system made by TOR VM was chosen as the comparator. Several innovative types of sectional matrix systems were introduced to the market with several thicknesses, heights, profiles of curvature, variation of wedges and separation clamps. These advancements have enabled dentists to create the most beneficial proximal contact surfaces and anatomically correct contours, both of which are critical for tooth periodontal complex protection.

In badly broken-down teeth, the sectional matrix should have a correct curved profile, making it possible to create a correct emergence profile in a cervico-occlusal direction. An increased proximal curvature (cervico-incisally) of the matrix band is required when the distance between the cervical cavity margin and the adjacent tooth increases. This is observed when the cervical cavity margin is in a more apical position. Thus, to select the correct matrix band, one must be aware of its maximum curvature. Besides the matrix bands should have enough extensions in a buccolingual direction to be able to restore the contact area efficiently.

Hard stainless steel sectional saddle matrices (TOR VM, Moscow, Russia) have a maximum curvature of ±0.7 mm compared to ±0.5 mm of the classical TORVM sectional matrix. The maximum curvature starts more cervically, making it easier to reach deeper margins. And these matrices offer more buccal and lingual wrap than traditional matrices.

The Bioclear Biofit matrices introduce new matrix technology and designs that claimed by the manufacturer to ensure ideal proximal composite contour. BioFit Matrix bands (Bioclear Matrix Systems; Tacoma, WA, USA) have the highest maximum curvature among all available matrices in the market (±0.9 mm). These matrix bands are contoured plastic (Mylar) sectional matrices with a placement tab that makes the matrix easy to place. Transparent matrices may allow better light transmission and allegedly more effective polymerization of the underlying resin composite. Mylar matrices also leave the composite more polished and contoured than traditional metal matrices which leave a more matte finish. In addition, the new shape of the Biofit matrices offers 30% more buccal/lingual and occlusal wrap than traditional matrices and can be used in cavities that are more open in a bucco-lingual direction. In addition, the matrix features a curved occlusal embrasure, which, if the matrix is well-positioned, shortens the finishing time of the occlusal embrasure with burs or disks.

The clinical performance of these matrices regarding obtaining optimum contact, contour and prevents overhangs is yet to be evaluated. Controlled randomized clinical trials- based on correctly adopted evaluation systems, are crucial for effective evidence-based dental knowledge and restorative practice. Thus, this study aims to contribute in providing evidence-based literature concerning current innovative matrixing systems and an evidence based clinical practice in the most critical situation which is restoring contacts in badly broken down teeth.

Enrollment

90 patients

Sex

All

Ages

18 to 45 years old

Volunteers

Accepts Healthy Volunteers

Inclusion criteria

  • Patients with posterior complex class II cavities to be restored with resin composite restorations.
  • 18 - 45 years.
  • Males or Females.
  • Good oral hygiene.
  • Co-operative patients approving to participate in the study.

Exclusion criteria

  • Poor oral hygiene.
  • Allergic history concerning methacrylates
  • Evidence of parafunctional habits.
  • Presence of malalignment of teeth

Trial design

Primary purpose

Treatment

Allocation

Randomized

Interventional model

Parallel Assignment

Masking

Double Blind

90 participants in 3 patient groups

Sectional matrix: Classic ring system
Experimental group
Description:
Sectional matrix: Classic ring system (TOR VM, Moscow, Russia)
Treatment:
Device: Sectional matrix: Classic ring system (TOR VM, Moscow, Russia)
BioFit Posterior Matrix System
Active Comparator group
Description:
BioFit Posterior Matrix System (Bioclear, Tacoma, Washington, USA).
Treatment:
Device: BioFit Posterior Matrix System
Saddle system
Active Comparator group
Description:
Saddle system (TOR VM, Moscow, Russia)
Treatment:
Device: Saddle system (TOR VM, Moscow, Russia)

Trial contacts and locations

1

Loading...

Data sourced from clinicaltrials.gov

Clinical trials

Find clinical trialsTrials by location
© Copyright 2026 Veeva Systems