Status
Conditions
About
Failed intubation is currently one of the most important factors leading to morbidity and mortality in anesthesia.
The development of supraglottic airway devices (SGDs), such as the intubating laryngeal tube, has revolutionized airway management, as these devices allow adequate ventilation and oxygenation in situations where ventilation and/or intubation via conventional means pose a challenge. Several publications describe the usefulness of such devices for salvaging ventilation in patients that cannot be intubated with direct laryngoscopy or who cannot be ventilated with a facemask. In these salvage situations, SGDs are highly effective in achieving adequate patient oxygenation.
Achieving effective oxygenation with an SGD and completely isolating the airway by intubation at the same time. This is now possible thanks to the so called supraglottic intubation devices (SGIDs). For that reason, we believe it is necessary to conduct a study that allows evaluation of the performance of this device in the context of daily clinical practice.
Its design characteristics, its capacity to be used in intubation applications, its soft and atraumatic materials as well as its disposability augur this product a significant expansion in the next few years. Nonetheless, no data are available on the success of intubation when the intubating laryngeal tube suction device (ILTSD) is used. The idea behind this study is to assess the possibilities to use the ITLSD device to intubate patients in regular anesthetic practice.
Full description
The development of supraglottic airway devices (SGDs), such as the intubating laryngeal tube, has revolutionized airway management, as these devices allow adequate ventilation and oxygenation in situations where ventilation and/or intubation via conventional means pose a challenge. It would seem ideal to be able to unify both techniques in one single device; in other words, achieving effective oxygenation with an SGD and completely isolating the airway by intubation at the same time. This is now possible thanks to the so-called supraglottic intubation devices (SGIDs). For that reason, we believe it is necessary to conduct a study that allows evaluation of the performance of this device in the context of daily clinical practice.
LOCATION: The study will be conducted at operating rooms serving inpatients at the Valencia Clinical University Hospital. Investigators will be anesthesiologists with long experience in fibroscopy and in the management of supraglottic devices used for intubation.
METHODOLOGY: Prospective observational study aimed at evaluating the success of intubation through an I-LTSD device in regular clinical practice.
Research population: The study population will be made up of adult patients undergoing elective surgery who require general anesthesia and endotracheal intubation. Patients will be included in a consecutive manner provided that selection criteria are met. All patients will be required to sign an informed consent form.
Study variables: Information on the following variables will be gathered:
Demographic variables: age, gender, weight, height
Clinical variables: American Society Anaesthesiology status
Concomitant conditions: presence of cardiovascular or respiratory conditions, liver or renal failure, history of gastroesophagic reflux.
Type of surgery to be performed
Difficult airway parameters:
Anesthetic agents used, including dose administered: propofol, fentanyl, others
Number of attempted laryngeal mask insertions
Repositioning maneuvers
Insertion time (in seconds)
Change for a different number
Expired tidal volume > 6-7 ml.kg-1,
Expired CO2 < 45 mm Hg
Seal pressure
Fiberoptic visualization
Ease of passage of nasogastric tube
Number and duration of intubation attempts through laryngeal mask
Presence of blood on removal of the device
Soreness of throat, painful swallowing /intensity (mild-moderate-severe)
Total anesthesia time
Baseline hemodynamic parameters (SpO2, E-T-CO2) and BIS value at pre-insertion (following induction of anesthesia), at 3 minutes after insertion of I-LTSD device, pre-intubation and immediately following tube removal.
PATIENT RECRUITMENT Once it has been ascertained that inclusion criteria are met, patients will be informed about the study and they will be invited to participate. If they agree, they will be asked to sign an informed consent form either in the pre-anesthesia unit or in the ward. This must be done well before the patient is taken to the operating room.
OPERATION ROOM PROCEDURE (OR) Once the patient is in the OR standard monitoring is performed (3-lead ECG, non invasive blood pressure measurements every 5 minutes and peripheral O2 saturation). In addition, anesthetic depth will also be monitored using a bispectral index (BIS) monitor (BIS-VISTA™ Monitoring System, Aspect Medical System Inc. USA). Pre-oxygenation with 100% oxygen will be performed through a facemask with the patient breathing normally (normal tidal volume).
Subsequently the anesthesiologist in charge will carry out induction of anesthesia following the standard procedure, using neuromuscular blocking agents at standard doses (preferably rocuronium at a dose of 0.6 mg/kg of ideal weight). A record will be kept of the dosage used for each of the drugs administered during anesthesia induction. Once the patient has lost consciousness, manual ventilation will be applied through a facemask until the device is inserted.
According to airway management clinical guidelines,, anesthetic depth is considered adequate for insertion of a supraglottic device when the following conditions are met: absence of palpebral reflex, absence of response to jaw subluxation and BIS value below 40. If on insertion of the I-LTSD device the patient reacts with avoidance movements, the dose of propofol (or of the hypnotic agent the anesthetist in change has decided to use) should be augmented in 50 mg-bolus increments until the anesthetic status of the patient is appropriate for insertion of the device. A record will be kept of the total number of additional boluses required (if any).
The anesthesiologist will then insert the I-LTSD device in accordance with the manufacturer's instructions to ensure optimal placement:
Once the I-LTSD device has been inserted:
Use of the fibroscope to facilitate endotracheal intubation is based on previous experience with these kinds of devices.
Training of the investigators in the procedures of the study:
The study will be carried out by physicians specializing in the fields of anesthesia and resuscitation who are in the habit of applying general anesthesia to patients undergoing surgery, and who routinely perform airway control by means of endotracheal intubation. They will also have used supraglottic devices for intubation in over 80 cases.
ESTIMATION SAMPLE SIZE& DATA ANALYSIS: According to published data, the success rate for other supraglottic devices ranges between 84 and 90% at the first attempt and between 95-100% overall. Considering that the upper limit of the 95% confidence interval acceptable for supraglottic devices should be lower than 2.5%, the required size of our sample should be of 30 patients. To compensate for potential losses to follow up, the total number of patients to be included will be 34.
The descriptive analysis of the data collected will be made by drawing up frequency tables for the nominal variables, and calculating measures of central tendency and dispersion for continuous variables. 95% confidence intervals will be estimated (95% CI) for the latter. For the clinical variables, Student's T test will be used for data related with quantitative variables if parameters show a normal distribution. If the distribution of parameters is abnormal the Mann-Whitney U test will be performed.
DURATION: The data recording period will be 5 months. Patients will be recruited consecutively provided that they comply with the inclusion criteria, they do not meet the exclusion criteria described above and they agree to participate in the study and sign the required informed consent form.
ETHICAL: The study will be conducted in accordance with the ethical requirements laid down in the Helsinki Declaration, revised in Edinburgh, Scotland in October 2000, in terms of human experimentation, as well as in accordance to Spanish Royal Decree 223 of 1 May 2004.
CONFIDENTIALITY: The study will be carried out within the framework of the Spanish Data Protection Law (Act 15 of 13 December 1999).