ClinicalTrials.Veeva

Menu

Far Infrared Therapy on Peripheral Artery Disease in Hemodialysis Patients

T

Taipei Veterans General Hospital

Status and phase

Unknown
Phase 4

Conditions

Peripheral Artery Disease

Treatments

Device: WSTM TY101 FIR emitter (Far infrared therapy)
Device: Placebo device

Study type

Interventional

Funder types

Other

Identifiers

NCT01095549
V99C1-010

Details and patient eligibility

About

The prevalence of peripheral artery disease (PAD) defined as ankle-brachial index (ABI) less than 0.9 was about 15~30% in patients with end stage renal disease (ESRD), which was higher than those with normal renal function. A lower ABI and a higher brachial-ankle pulse wave velocity (baPWV) are good markers to predict the risk of PAD and atherosclerosis respectively. In addition, baPWV>2,100 cm/s was shown to be related to potential PAD. ABI <0.9 was positively associated with vascular access failure in hemodialysis (HD) patients and our previous study has demonstrated that far infrared (FIR) therapy can improve access flow and unassisted patency of atrioventricular (AV) fistula.

The aims of this study are to evaluate (1) the frequency of and (2) risk factors associated with abnormal ABI and PWV as well as (3) the effect of FIR on ABI and PWV and markers related to endothelial dysfunction in HD patients.

Full description

In this study, 300 HD patients will be enrolled to receive ABI and baPWV and about 90 patients (30% according to the literature review) who have abnormal ABI (<0.9) or baPWV (>2100 cm/sec) will be randomly allocated to FIR group (receiving FIR therapy for 40 minutes thrice weekly) and control group (without FIR therapy). In patients with abnormal ABI or baPWV, the effect of single or one-year treatment of FIR on the following items will be studied: (1) ABI, (2) baPWV and (3) markers related to endothelial dysfunction [including low and high density lipoprotein cholesterol (LDL and HDL), asymmetric dimethylarginine (ADMA), hypersensitive C-reactive protein (hsCRP), matrix metalloproteinase-9 (MMP-9)]. The effect of FIR on PAD or cardiovascular events during one year of follow-up will also be studied.

This study will allow us to identify the frequency of and the risk factors associated with abnormal ABI & PWV as well as the effect of single or one-year FIR therapy on ABI & PWV in HD patients.

Enrollment

300 estimated patients

Sex

All

Ages

18 to 90 years old

Volunteers

No Healthy Volunteers

Inclusion criteria

  • In this study, we will include 300 patients who have received 4 hours of maintenance HD therapy three times weekly for at least 3 months

Exclusion criteria

  • Patients with life expectancy less than 1 year
  • Patients with history of active malignancy

Trial design

Primary purpose

Treatment

Allocation

Randomized

Interventional model

Parallel Assignment

Masking

Single Blind

300 participants in 2 patient groups, including a placebo group

Control group
Placebo Comparator group
Description:
HD patients who will not receive far infrared therapy in this study.
Treatment:
Device: Placebo device
Far infrared therapy
Experimental group
Description:
In this study, a WSTM TY101 FIR emitter (WS Far Infrared Medical Technology Co., Ltd., Taipei, Taiwan) will be used for FIR therapy. The electrified ceramic plates of this emitter generate electromagnetic waves with wavelengths in the range between 3 and 25 μm (a peak between 5 to 6 μm). The irradiating power density is 10 and 20 mili watt\<mw\>/cm2 when the top radiator is set at a distance between 30 and 20 cm above the skin surface respectively. In this study, the top radiator will be set at a height of 25 cm above the surface of bilateral lower legs and the treatment time will be set at 40 minutes for patients on maintenance HD.
Treatment:
Device: WSTM TY101 FIR emitter (Far infrared therapy)

Trial contacts and locations

2

Loading...

Central trial contact

Hsiao-Di Cheng, BSc