ClinicalTrials.Veeva

Menu

Feasibility of Endovascular Repair Of Ascending Aortic Pathologies

R

Rodney A. White, MD

Status

Enrolling

Conditions

Pseudoaneurysm
Intramural Hematoma
Penetrating Ulcer
Aortic Dissection

Treatments

Device: Endovascular repair with Valiant PS-IDE Stent Graft

Study type

Interventional

Funder types

Other

Identifiers

NCT02201589
PSIDE:Ascending Thoracic Aorta

Details and patient eligibility

About

The purpose of this study is to investigate the outcome of patients with pathologies of the ascending thoracic aorta (diseases in the great blood vessel or artery that leads away from the heart) including type A aortic dissection, retrograde type A aortic dissection, intramural hematoma, penetrating ulcer or pseudoaneurysm who are suitable for endovascular (within the vessel) repair with the Medtronic Valiant PS-IDE (Physician Sponsored-Investigational Device Exemption) Stent Graft. Type A aortic dissection is a condition where blood passes through the inner lining or between the layers of the blood vessel from a tear in the aortic wall (dissection) in the ascending aorta; a retrograde Type A aortic dissection is a condition where the dissection or tear in the ascending aorta starts from the descending aorta; an intramural hematoma is a collection of clotted blood within the aortic wall; a penetrating ulcer has a plaque or clot within the wall and a pseudoaneurysm is a false aneurysm . If left untreated in any of these conditions, the aorta can enlarge and rupture causing injury or death. The plan for these patients is to repair the ascending thoracic aorta using the Medtronic Valiant PS-IDE Stent Graft with the Captivia Delivery System. The Valiant Captivia has been evaluated worldwide and used extensively in patients with type B (descending) thoracic aortic dissection. Since the dissections in the ascending aortas mirror that of the descending aorta, it is expected that this stent graft will deliver similar performance and endurance in patients with type A aortic dissection. The investigators expect to reroute the blood to the true lumen (the inner space within the blood vessel) by covering the proximal (nearest to the heart) tear with the stent graft. The stent graft is a stent frame made from Nitinol wire and covered with an expandable material made of a polyester material. This new study will determine how well the device works to treat dissections, intramural hematomas, penetrating ulcers and pseudoaneurysms in the ascending thoracic aorta.

Full description

This is a prospective study with 20 patients planned to be enrolled. Patients who participate will be followed for 5 years after the surgery in which the stent graft was implanted. This will include the following schedule: A CT with and without contrast and echocardiogram 30 days after the Medtronic device is implanted, CT with and without contrast at 6 and 12 months post procedure and once a year from 2 years thru 5 years after the implant.

Enrollment

20 estimated patients

Sex

All

Ages

18+ years old

Volunteers

No Healthy Volunteers

Inclusion criteria

  • Patient must have a Type A thoracic aortic dissection, retrograde Type A thoracic aortic dissection, intramural hematoma, penetrating ulcer or pseudoaneurysm of the ascending thoracic aorta affecting the area between the Sinus of Valsalva and the innominate artery orifice (with no involvement of the aortic valve) and be considered candidates for endovascular repair;
  • Patient must also have at least one cm proximal and distal landing zones in the ascending aorta between 28-44 mm in diameter;
  • The patient must be deemed high-risk surgical candidate according to the following established criteria: ASA (American Society of Anesthesiologists) class IV.

Exclusion criteria

  • Pregnant or pediatric patients (younger than 21 years of age);
  • Patients who have a condition that threatens to infect the stent graft/aortic valve prosthesis;
  • Patients with allergies to the stent graft material;
  • Patients or their legally authorized representatives who do not sign the informed consent;
  • Patients with expected survival less than one year.

Trial design

Primary purpose

Treatment

Allocation

N/A

Interventional model

Single Group Assignment

Masking

None (Open label)

20 participants in 1 patient group

Endovascular repair of ascending aorta
Experimental group
Description:
Endovascular repair with Valiant PS-IDE Stent Graft
Treatment:
Device: Endovascular repair with Valiant PS-IDE Stent Graft

Trial contacts and locations

3

Loading...

Central trial contact

Ali Khoynezhad, M. D., PhD; Rodney A White, M.D.

Data sourced from clinicaltrials.gov

Clinical trials

Find clinical trialsTrials by location
© Copyright 2026 Veeva Systems