Status
Conditions
Treatments
About
To assess the safety and feasibility of Transcatheter Aortic Valve Replacement (TAVR) with commercially available bioprostheses in patients with severe, symptomatic aortic stenosis (AS) who are low-risk (STS score ≤3%) for surgical aortic valve replacement (SAVR).
Full description
Trial Objectives: To assess the safety and feasibility of Transcatheter Aortic Valve Replacement (TAVR) with commercially available bioprostheses in patients with severe, symptomatic aortic stenosis (AS) who are low-risk (STS score ≤3%) for surgical aortic valve replacement (SAVR).
Methodology: This is a multicenter, prospective trial of TAVR in low-risk patients at up to twelve sites in the United States. The trial will have three arms. The first will comprise 200 patients undergoing transfemoral TAVR. The second arm will comprise200 closely matched historical controls who underwent isolated bioprosthetic SAVR.
Historical controls will be selected from among patients at the same site who have undergone isolated bioprosthetic SAVR within the previous 36 months. TAVR patients will then be matched to SAVR patients using STS database variables to perform propensity matching, including (but not limited to) age, gender, race, ethnicity, STS score, and valve prosthesis size. Once the historical matched controls are identified, detailed chart review will abstract in-hospital and 30-day outcomes for the SAVR cohort.
The third arm of the trial will comprise a registry of TAVR in up to 100 low-risk patients with bicuspid aortic valve. The results from the registry arm will be analyzed independently.
Primary Efficacy Endpoint: All-cause mortality at 30 days following transfemoral TAVR vs. bioprosthetic SAVR.
Primary Safety Endpoint: Defined as the composite of major adverse events at 30 days:
a. all-cause mortality c. spontaneous myocardial infarction (MI) d. reintervention: defined as any cardiac surgery or percutaneous reintervention that repairs, alters, or replaces a previously implanted aortic valve e. VARC life-threatening bleeding f. Increase in serum creatinine to ≥300% (>3x increase compared to baseline) OR serum creatinine ≥4.0 mg/dL with an acute increase ≥0.5 mg/dL OR new requirement for dialysis g. coronary artery obstruction requiring percutaneous or surgical intervention h. VARC major vascular complication i. cardiac tamponade j. cardiac perforation k. pericarditis l. mediastinitis m. hemolysis n. infective endocarditis o. moderate or severe aortic insufficiency p. significant aortic stenosis q. permanent pacemaker implantation r. new-onset atrial fibrillation
Secondary Endpoints (TAVR Cohort):
Major adverse cardiovascular and cerebrovascular events (MACCE) at 30 days, 6 months, 12 months, and 2, 3, 4 and 5 years, defined as the composite of:
The occurrence of the individual components of MACCE at 30 days, 6 months, 12 months, and 2, 3, 4, and 5 years (including stoke).
The composite of major adverse device events post-procedure, and at 6 months, 1 year, and 2, 3, 4, 5 years
VARC major vascular complications, at 30 days and 1 year
VARC life-threatening or disabling bleeding, at 30 days and 1 year
Technical success upon exit from the operating room or catheterization laboratory, defined as all of the following:
Device success at 30 days and 1 year, defined as all of the following:
No migration, erosion, embolization, detachment, fracture, hemolysis requiring transfusion, thrombosis, or endocarditis 2. Intended performance of the heart valve: no prosthesis-patient mismatch, mean aortic valve gradient <20 mm Hg OR peak velocity <3 m/s, AND no moderate or severe bioprosthetic valve regurgitation 8. Procedural success at 30 days, defined as device success AND no major adverse device events 9. Bioprosthetic valve regurgitation, defined as either moderate or severe aortic regurgitation OR moderate or severe paravalvular leak, at hospital discharge, 12 months, and 2, 3, 4, and 5 years 10. Incidence of new-onset atrial fibrillation at hospital discharge, and at 30 days, 12 months, and 2, 3, 4, and 5 years.
Conduction disturbance requiring permanent pacemaker implantation at hospital discharge, 12 months, and 2, 3, 4, and 5 years.
Change in NYHA class from baseline to 30 days, baseline to 6 months, baseline to 12 months, and baseline to 2-5 years.
Change in distance walked during 6-minute walk test from baseline to 12 months.
Change in responses to the short form Kansas City Cardiomyopathy Questionnaire (KCCQ-12) from baseline to 12 months.
Echocardiographic assessment of the bioprosthetic valve post-procedure, at 12 months, and at years 2-5, including (but not limited to):
a. aortic valve mean gradient, maximum gradient, and peak velocity b. calculated aortic valve area c. degree of bioprosthetic valve regurgitation 16. Assessment for subclinical leaflet thrombosis with multislice computed tomography, or transesophageal echocardiography if GFR <50 mL/min/m2, at 1 to 2 months.
Individual patient level Success all of the following and device success:
No re-hospitalizations or re-interventions for the underlying condition (e.g., HF)
Return to prior living arrangement (or equivalent)
Improvement vs. baseline in symptoms (NYHA Class decrease ≥ 1)
Improvement vs. baseline in functional status (6MWT increase ≥ 50 meters)
Improvement vs. baseline in QoL (KCCQ increase ≥ 10)
Number of Trial Sites: 12
Sample Size: 200 consecutive patients and 200 historical controls, and an additional 100 (up to) patients with bicuspid aortic valve
Patient Population: Patients with severe, symptomatic AS who are determined by the Heart Team to be at low surgical risk (STS score ≤3%).
Enrollment
Sex
Volunteers
Inclusion criteria
Severe, degenerative AS, defined as:
Symptomatic AS, defined as a history of at least one of the following:
The Heart Team, including at least one cardiothoracic surgeon and one interventional cardiologist, deem the patient to be reasonable for transfemoral TAVR with a commercially available bioprosthetic valve
The Heart Team agrees that the patient is low-risk, quantified by an estimated risk of ≤3% by the calculated STS score for operative mortality at 30 days; AND agrees that SAVR would be an appropriate therapy if offered.
The Heart Team agrees that transfemoral TAVR is anatomically feasible, based upon multislice CT measurements
Procedure status is elective
Expected survival is at least 24 months
For the bicuspid cohort only:
Aortic Stenosis of a bicuspid aortic valve
Exclusion criteria
Concomitant disease of another heart valve or the aorta that requires either transcatheter or surgical intervention
Any condition that is considered a contraindication for placement of a bioprosthetic aortic valve (e.g. patient requires a mechanical aortic valve)
Aortic stenosis secondary to a bicuspid aortic valve (except for the bicuspid valve cohort)
Prior bioprosthetic surgical aortic valve replacement
Mechanical heart valve in another position
End-stage renal disease requiring hemodialysis or peritoneal dialysis, or a creatinine clearance <20 cc/min
Left ventricular ejection fraction <20%
Recent (<6 months) history of stroke or transient ischemic attack
Symptomatic carotid or vertebral artery disease, or recent (<6 weeks) surgical or endovascular treatment of carotid stenosis
Any contraindication to oral antiplatelet or anticoagulation therapy following the procedure, including recent or ongoing bleeding, or HASBLED score >3
Severe coronary artery disease that is unrevascularized
Recent (<30 days) acute myocardial infarction
Patient cannot undergo transfemoral TAVR for anatomic reasons (as determined by supplemental imaging studies); this would include inadequate size of iliofemoral access vessels or an aortic annulus size that is not accommodated by the commercially available valves
Any comorbidity not captured by the STS score that would make SAVR high risk, as determined by a cardiothoracic surgeon who is a member of the heart team; this includes:
Ongoing sepsis or infective endocarditis
Recent (<30 days) or ongoing bleeding that would preclude treatment with anticoagulant or antiplatelet therapy, including recent gastrointestinal bleeding
Uncontrolled atrial fibrillation (resting heart rate >120 beats per minute)
Severe chronic obstructive pulmonary disease, as demonstrated by forced expiratory volume (FEV1) <750 cc
Liver failure with Childs class C or D
Pre-procedure shock, inotropes, mechanical assist device, or cardiac arrest
Pregnancy or intent to become pregnant prior to completion of all protocol follow-up procedures
Known allergy to warfarin or aspirin
Primary purpose
Allocation
Interventional model
Masking
277 participants in 3 patient groups
Loading...
Data sourced from clinicaltrials.gov
Clinical trials
Research sites
Resources
Legal