ClinicalTrials.Veeva

Menu

Feasibility Trial of the F2 Filter and Delivery System for Embolic Protection During TAVR

E

EnCompass Technologies

Status and phase

Enrolling
Early Phase 1

Conditions

Aortic Stenosis

Treatments

Device: F2 filter and delivery system

Study type

Interventional

Funder types

Industry

Identifiers

Details and patient eligibility

About

The goal of this clinical trial is to learn about the safety and performance of the F2 device for cerebral embolic protection in participants with symptomatic aortic stenosis underdoing a Transcatheter Aortic Valve replacement procedure.

Participants will complete several neurocognitive assessments and an MRI procedure.

Full description

The goal of this clinical trial is to learn about the safety and performance of the F2 device for cerebral embolic protection in participants with symptomatic aortic stenosis underdoing a transcatheter aortic valve replacement procedure. The F2 device is inserted via a transfemoral approach and positioned in the aorta to cover and protect the three great cerebral vessels from any debris released during the valve replacement procedure. The F2 device remains in place during the aortic valve replacement procedure. After the valve is placed, the F2 device is removed.

Enrollment

10 estimated patients

Sex

All

Ages

22+ years old

Volunteers

No Healthy Volunteers

Inclusion criteria

criteria:

  1. Age ≥ 22 years.
  2. The patient meets the established criteria and indications for commercially available TAVR (Edwards/Medtronic) for transfemoral access.
  3. Montreal Cognitive Assessment (MoCA) score ≥ 26 at screening.
  4. The patient is willing and able to comply with protocol-specified follow-up evaluations.
  5. The patient or legally authorized representative is able and willing to provide written informed consent.

Exclusion criteria

  1. Contraindications to MRI (e.g., subjects with MR unsafe implants including implantable temporary or permanent pacemaker or defibrillator, metal implants in field of view, metallic fragments, clips, or devices in the brain or eye before TAVR procedure, or claustrophobia).

  2. Severe peripheral arterial, abdominal aortic, or thoracic aortic disease that precludes delivery sheath vascular access or filter deployment.

  3. Patients in whom the aortic arch is heavily calcified, severely atheromatous, or severely tortuous.

  4. Ascending aortic diameter > 38 mm or transverse aortic diameter > 27 mm.

  5. Evidence of an acute myocardial infarction within 1 month before TAVR.

  6. Pre-existing prosthetic heart valve or prosthetic ring in any position.

  7. Known intracardiac thrombus.

  8. Severe allergy or known hypersensitivity or contraindication to aspirin, heparin/bivalirudin, clopidogrel, nitinol, stainless steel alloy, and/or contrast sensitivity that cannot be adequately pre-medicated.

  9. History of bleeding diathesis or coagulopathy or patients in whom anti-platelet and/or anticoagulant therapy is contraindicated.

  10. Patients who refuse blood transfusion.

  11. Active peptic ulcer or history of upper gastrointestinal (GI) bleeding within the prior 3 months.

  12. Recent (within 6 months) CVA or a TIA.

  13. Renal insufficiency (creatinine > 2.5 mg/dL or GFR < 30) and/or renal replacement therapy at the time of screening.

  14. Patients with hepatic failure (Child-Pugh class C).

  15. Patients with hypercoagulable states that cannot be corrected by additional periprocedural heparin.

  16. Patients presenting with cardiogenic shock or requiring vasopressor or inotropic support at the time of the index procedure.

  17. Severe ventricular dysfunction with left ventricular ejection fraction (LVEF) < 20%.

  18. Life expectancy < 12 months.

  19. Currently participating in an investigational drug or another device study that has not completed the initial primary endpoint evaluation (e.g., long term follow-up study/continued access study subjects are able to be included).

  20. Subjects who have had treatment with any other investigational device within 30 days prior to study enrollment.

  21. Planned surgery or invasive procedure within 30 days following the index procedure (TAVR with F2 Filter).

  22. Patients planned to undergo any other cardiac surgical or interventional procedure (e.g., concurrent coronary revascularization) during the TAVR procedure or within 10 days prior to the TAVR procedure. NOTE: Balloon valvuloplasty during TAVR is permitted. Diagnostic cardiac catheterization is permitted within 10 days prior to the TAVR procedure.

  23. Patients with known mental or physical illness or known history of substance abuse that may cause non-compliance with the protocol or confound the data interpretation.

  24. Females who are pregnant or nursing or plan to become pregnant during their participation in the study. Female subjects of child-bearing potential must have a negative pregnancy test at screening.

  25. Any other condition that in the opinion of the investigator, precludes study participation or poses a significant hazard to the patient.

Trial design

Primary purpose

Device Feasibility

Allocation

N/A

Interventional model

Single Group Assignment

Masking

None (Open label)

10 participants in 1 patient group

Intervention
Experimental group
Description:
Placement of the F2 device in the aorta to cover the great cerebral vessels.
Treatment:
Device: F2 filter and delivery system

Trial contacts and locations

1

Loading...

Central trial contact

Kathleen Calderon; Francis Duhay, MD

Data sourced from clinicaltrials.gov

Clinical trials

Find clinical trialsTrials by location
© Copyright 2025 Veeva Systems