Status
Conditions
Treatments
About
The EPYGON VALVE is an innovative mitral valve, intended for valve replacement of a native mitral valve through a minimally invasive implant procedure by means of a dedicated implant device.
The EPYGON VALVE is a bio prosthesis, composed by a functional assembly of bovine pericardium on a NiTinol stent.
The purpose of this trial is to assess the safety and feasibility of the Epygon™ Transcatheter mitral valve and the transapical delivery system, in adult patients with severe, symptomatic mitral regurgitation.
Enrollment
Sex
Ages
Volunteers
Inclusion criteria
Exclusion criteria
Patients involved in other clinical assessments for drugs or devices that could interfere or alter the study endpoints.
Patients with clinical/anatomical conditions unsuitable for a transapical surgical approach.
Patients who have previously undergone implantation of a transcatheter aortic valve prosthesis.
Patients with previous implantation of a mitral heart valve prosthesis.
Patients with previous implantation of a mitral annuloplasty ring.
Patients needing emergency or life-saving interventions.
Patients with a heavily calcified mitral annulus and/or anterior mitral leaflet.
Patients with active infection or endocarditis (suspect endocarditis included).
Patients with echocardiographic evidence of intracardiac mass or thrombus.
Patients which suffered an acute myocardial infarction within 30 days of the intended treatment (defined as: Q wave MI, or non-Q wave MI with elevation of CK-MB ≥ 3 times normal in the absence of pathological Q waves), if no assay for CK-MB was performed, elevation of CK level to >2 times normal without new Q waves, or elevated Troponin level is also considered a non-Q wave MI).
Patients with an active peptic ulcer or upper GI bleeding within the prior 30 days.
Patients with a documented allergy towards contrast media, and to any compound of the investigated medical device.
Patients that have neurological disease severely affecting ambulation or day to day functioning.
Patients with any stroke within the prior 30 days.
Patients with senile dementia, according to the advice from a specialized neurologist.
Patients in whom transesophageal echocardiography (TEE) is contraindicated since TEE is used for both preoperative screening and guidance during implant procedure.
Patients who is unwilling or deemed by the Investigator to be unwilling to comply with the requirements of the protocol, or subject with a history of non-compliance.
Patients unable to understand and sign the Informed Consent Form in absence of legal representative.
Patients with a lack of capacity to consent.
Patients unable to read and write.
Patients with left ventricular apex aneurysm;
Patients with aorto-mitral angle <120°;
Patients with a systolic/diastolic mitral valve area assessed as not compatible with the sizing policy matrix defined by the Sponsor.
Patients with ventricular morphology (position of papillary muscles, ventricular wall hypertrophy) unsuitable with the study valve design;
Patients with aorto-mitral angle <120°;
Patients with a systolic/diastolic mitral valve area assessed as not compatible with the sizing policy matrix defined by the Sponsor.
Primary purpose
Allocation
Interventional model
Masking
40 participants in 1 patient group
Loading...
Central trial contact
Christophe Giot
Data sourced from clinicaltrials.gov
Clinical trials
Research sites
Resources
Legal