Fluid Responsiveness Evaluation by a Non-invasive Method in CHildren (FRENCH)

U

University Hospital of Bordeaux

Status

Completed

Conditions

Circulatory Failure (Shock)

Treatments

Procedure: Non interventional study (study of diagnostic accuracy with an extra echocardiographic assessment).

Study type

Observational

Funder types

Other

Identifiers

NCT05919719
CHUBX 2021/48

Details and patient eligibility

About

In this study, the investigators aim to validate a non-invasive marker of fluid-responsiveness in children with acute circulatory failure based on standardized abdominal compression. This would allow physicians to identify which patient could benefit from a fluid expansion, thus avoiding a potentially useless or even dangerous fluid expansion, leading to fluid overload. To this end, the investigators will evaluate the diagnostic accuracy (sensitivity and specificity) of stroke volume variation induced by standardized abdominal compression for the diagnosis of fluid responsiveness (based on the gold-standard test: significant increase in cardiac index after fluid expansion).

Full description

Fluid expansion is the cornerstone of acute circulatory failure treatment in children Although this therapy drastically reduced mortality, several studies in recent years have highlighted the adverse effects of excessive fluid expansion (leading to fluid overload). Currently, the search for indicators to predict fluid responsiveness is a major issue in intensive care. These indicators are based on Franck-Starling's law: if small changes in preload lead to an increase in cardiac output, then fluid responsiveness can be expected. However, in children, the only validated indicator (respiratory variability of peak aortic velocity) can only be used in the absence of any spontaneous respiratory movement, a rare situation in practice. Recently, two pediatric studies investigated a simple clinical test: hepatic or abdominal compression. This clinical maneuver, by increasing venous return via mobilization of the hepato-splanchnic reserve, induces a transient and reversible preload increase. The evaluation of the hemodynamic effects of this "endogenous fluid expansion" allowed, according to the authors, to accurately predict fluid responsiveness. However, several factors reduce the applicability of these results: the small number of studies on this subject, the smaller volume of fluid used than in clinical practice, and the population studied, composed almost exclusively of children in postoperative of cardiac surgery.

In this study, the investigators will evaluate the diagnostic accuracy of abdominal compression for the diagnosis of fluid responsiveness in children with acute circulatory failure, hospitalized in pediatric intensive care unit (PICU) for a medical or a non-cardiac surgical condition, for whom a fluid expansion was prescribed by the physician in charge. The index test will be the stroke volume variation following a standardized abdominal compression (before fluid expansion). The gold standard test will be the variation of cardiac output between baseline and after fluid expansion, a variation > 15% defining fluid responsiveness.

In this non interventional study of diagnostic accuracy, patients will undergo an extra echocardiographic assessment, but no supplemental blood test or invasive parameters will be collected. Simple clinical parameters will be collected within 4 hours after the fluid expansion. Patients will be follow-up until PICU discharge.

Enrollment

21 patients

Sex

All

Ages

1 minute to 14 years old

Volunteers

No Healthy Volunteers

Inclusion criteria

  • Age lower than 15 years old
  • Prescription of a 10 to 20ml/kg crystalloid fluid expansion by the physician in charge
  • Acute circulatory failure defined by the association of an A criteria (increase of heart rate more than two standard deviation for the age, decrease of systolic or mean blood pressure more than two standard deviation for ) and a B criteria (lactate more than 2 mmol/L, oliguria less than 1mL/kg/h, a capillary filling time more than 3 seconds, mottling)
  • Patient hospitalized in PICU

Exclusion criteria

  • Prematurity (term below 37 gestational week).
  • Acute cardiogenic pulmonary edema
  • Hemodynamic instability making the delay necessary for abdominal compression and ultrasonography dangerous for the patient
  • Non corrected congenital cardiopathy, or inferior to 15 days postoperative.
  • Intra-abdominal hypertension or painful abdominal palpation
  • Abdominal surgery in the last 15 days
  • Supine position contraindicated or deleterious
  • No investigator available to assess ultrasonographic measures
  • Impairment of echocardiographic acoustic window or restless patient making ultrasonography impossible

Trial design

21 participants in 1 patient group

study of diagnostic accuracy
Description:
Patients included in this study would have received fluid expansion in all cases, as the prescription of 10 to 20ml/kg crystalloid fluid expansion by the physician in charge is the main inclusion criterion.
Treatment:
Procedure: Non interventional study (study of diagnostic accuracy with an extra echocardiographic assessment).