ClinicalTrials.Veeva

Menu

HD-tDCs to Improve Upper Extremity Function in Patients With Acute Middle Cerebral Artery Stroke

Penn State Health logo

Penn State Health

Status

Withdrawn

Conditions

Middle Cerebral Artery Stroke

Treatments

Device: Sham Stimulation
Device: Soterix MxN Neuromodulation device

Study type

Interventional

Funder types

Other

Identifiers

NCT04000269
None at this time

Details and patient eligibility

About

To determine if using targeted high definition transcranial direct current stimulation can improve upper extremity motor function in patients with subacute middle cerebral artery (MCA) stroke.

Full description

Current research suggests there may be potential benefit using high definition transcranial direct current stimulation in patients with upper extremity hemiparesis secondary to an ischemic stroke. The intervention has effects on the damaged neurons within the person's brain after stroke possibly amplifying the body's own healing process. These data are compelling but not always statistically significant, which could be due to several reasons. One is the lack of a definitive protocol involving timing of the intervention relative to therapy, lead placement, an unclear dose-response relationship, and variable conductance of tissue and skull thickness. Hummel et al (2008) suggested that stimulation during or before intensive therapy yielded improved motor function or reaction time than when no therapy was given around the stimulation. Several other review articles and studies suggest using both high definition tDCS, which increases the focality of the current, and/or using neurotargeting software that uses the patient's own CT/MRI in the computation of the electrical montage can create a more personalized tDCS regimen.7,11,12 This study plans to do both. The Soterix MxN neuromodulation system has been used in multiple studies and has a targeting system that would help ensure both ideal current, more focal stimulation and optimal lead placements is essential as according to Datta et al (2011). Lesions within the brain may alter the flow of current through that area. The software system, HD-Targets, will be used that takes the patient's own MRI to account for variabilities in skull thickness, lesion size/location/composition, fluid density, and cerebrospinal fluid presence. These variabilities are used in the computer algorithm that simulates current flow through that specific participant's brain to get to the desired target area with the least amount of current and decreased stimulation of undesired areas. The investigators will examine these patients before and after treatment and compare the two groups, treatment group and sham group, after they receive 10 sessions of 20minutes along with their regular course of physical, occupational, or speech therapy over the course of their inpatient rehab stay.

Subjects will be given high definition transcranial direct current stimulation (tDCS) via a Soterix MxN HD-tDCS stimulator. This device is for investigational use only at this time and is not FDA approved. However, it has been used in several multicenter and randomized control trials that are detailed below in Appendix 1. The patient's MRi will be sent out to Soterix where they will manually input the variations in skull thickness, fluid density, lesion size, cerebrospinal fluid, and gray/white matter variabilities. They will then run the algorithm with HD-Targets, sophisticated current simulating software, to obtain optimal electrode placement to target the primary motor cortex (M1 area), the region of the brain that is responsible for movement, of each individual patient. Another issue with tDCs is maintaining optimal connections between the patient's scalp and the electrodes. Sotetrix HD-tDCs uses SmartScan™ to assure proper lead contact with initial set-up to adjust electrodes and head-gear for optimal fit. During stimulation, SmartScan™ provides a constant indication of electrode quality and can be monitored during adjustments to assure continuous lead contact.

Sex

All

Ages

18 to 90 years old

Volunteers

No Healthy Volunteers

Inclusion criteria

  1. Adults 18-90 years old
  2. Diagnosed with middle cerebral artery ischemic stroke
  3. Upper extremity movement deficits
  4. Cardiorespiratory function is stable
  5. Admitted to acute inpatient rehabilitation
  6. Intact corticospinal tract

Exclusion criteria

  1. Previous stroke
  2. Pre-stoke weakness or disability in the paretic arm
  3. Severe neglect
  4. Acute exacerbation of heart failure or COPD
  5. Severe aphasia
  6. Decisional Impairment
  7. Pregnant or nursing women
  8. Prisoner
  9. Skin disorder or wound of scalp
  10. Seizure disorder

Trial design

Primary purpose

Treatment

Allocation

Randomized

Interventional model

Parallel Assignment

Masking

Double Blind

0 participants in 2 patient groups

Treatment Group
Experimental group
Description:
Treatment with 'Soterix MxN Neuromodulation device (high definition transcranial direct current stimulator) using HD-Targets for optimal neural targeting will be provided to participants and will include 20 minutes of stimulation coupled with conventional OT treatment during and after the intervention. There will be a total of 10 sessions over about a 2 week period.
Treatment:
Device: Soterix MxN Neuromodulation device
Sham group
Sham Comparator group
Description:
Sham stimulation will consist of using the devices auto-sham feature. The exact same setup/device will be used during both groups. This is considered a control for the experiment. Both groups will receive similar physical occupational and speech therapy
Treatment:
Device: Sham Stimulation

Trial contacts and locations