ClinicalTrials.Veeva

Menu

High Versus Low Bicarbonate Bath in Critically-ill Patients Receiving Continuous Renal Replacement Therapy

Mayo Clinic logo

Mayo Clinic

Status and phase

Withdrawn
Phase 4

Conditions

Acute Kidney Failure
Acute Kidney Injury
Metabolic Acidosis

Treatments

Drug: High Bicarbonate solution (32 mmol/L)
Drug: Low bicarbonate solution (22 mmol/L)

Study type

Interventional

Funder types

Other

Identifiers

NCT03846258
18-010147

Details and patient eligibility

About

Researchers are trying to determine which dialysis solution, low bicarbonate fluid (22 mmol/L) or high bicarbonate fluid (32 mmol/L), is better in subjects with acute kidney injury (acute kidney failure) and metabolic acidosis that are admitted to the intensive care unit and require continuous renal replacement therapy (also known as continuous dialysis).

Full description

This is a prospective randomized trial that will be conducted at Mayo Clinic in Rochester Minnesota. It will be based on Good Clinical Practice Standards and performed under IRB supervision. This will be a pragmatic clinical trial due to the nature of the intervention and short interval for making a clinical decision. While dialysis in general is valid in cases of severe AKI and metabolic acidosis, there remains uncertainty as to which replacement fluid to use. In one retrospective study, using high bicarbonate replacement fluid was associated with worse outcomes, even after accounting for several important confounders. While this intervention is valid in cases of severe metabolic acidosis (pH<7), there has not been much data to support the use of either intervention in cases of any metabolic acidosis in general.

While both interventions are equally valid, to our knowledge, there is no randomized clinical trial evaluating the difference of either intervention on outcomes. There is limited evidence in the literature on benefit or harm associated with either of the interventions on the outcomes thus generating a clinical equipoise. This pivotal study should help guide nephrologists and intensivists on the appropriate prescription of CRRT.

Sex

All

Ages

18 to 100 years old

Volunteers

No Healthy Volunteers

Inclusion and exclusion criteria

Inclusion Criteria

  • Adult patients (≥ 18 years of age)
  • Ability to obtain informed consent, either from patient or legally authorized representative (LAR)
  • Diagnosis of AKI according to KDIGO definition [an increase in serum creatinine concentration of greater than or equal to 0.3 mg/dL within the first 48 hours of injury, a relative increase in serum creatinine of greater than or equal to 50% (1.5-fold from baseline) within the first 7 days of injury, or a reduction in urine output (<0.5 mL/kg/h for more than 6 hours)]
  • CRRT initiated for the first time during current ICU admission.
  • Bicarbonate ≤ 22 mEq/L
  • Arterial pH between 7.05 and 7.25(if an ABG is not available, venous pH must be between 7.00 and 7.20)

Exclusion Criteria

  • Pregnancy (women of child-bearing potential must have a negative pregnancy test)

  • Diagnosis of End-Stage renal disease and receiving Hemodialysis or peritoneal dialysis prior to ICU admission (this information will be easily obtained by the nephrology team)

  • Arterial pH <7.05 or >7.25 (if an ABG is not available, Venous pH <7.00 or >7.20)

  • Potassium level >6.0 mmol/L

  • Severe acute liver failure meeting all the following criteria):

    • INR >2
    • AST/ALT more than 500 U/L and
    • Bilirubin more than 12 mg/dL)
  • Previous enrollment in this study

Trial design

Primary purpose

Treatment

Allocation

Randomized

Interventional model

Parallel Assignment

Masking

Single Blind

0 participants in 2 patient groups

Low bicarbonate arm (22 mmol/L)
Active Comparator group
Description:
PHOXILLUM solutions are used as a replacement solution in Continuous Renal Replacement Therapy. The one to be used in this study has bicarbonate concentration of 22 mmol/L.
Treatment:
Drug: Low bicarbonate solution (22 mmol/L)
High Bicarbonate (32 mmol/L)
Active Comparator group
Description:
PrismaSATE is another replacement solution used in Continuous Renal Replacement Therapy. The one to be used in this study has bicarbonate concentration of 32 mmol/L.
Treatment:
Drug: High Bicarbonate solution (32 mmol/L)

Trial contacts and locations

1

Loading...

Data sourced from clinicaltrials.gov

Clinical trials

Find clinical trialsTrials by location
© Copyright 2025 Veeva Systems