ClinicalTrials.Veeva

Menu

HIS Alternative II - UK Site

I

Imperial College Healthcare NHS Trust

Status

Enrolling

Conditions

Left Bundle-Branch Block
Heart Failure

Treatments

Device: HIS/LBB pacing
Device: LV pacing

Study type

Interventional

Funder types

Other

Identifiers

NCT05814263
22HH7978

Details and patient eligibility

About

The study will investigate the feasibility of using direct HIS pacing or left bundle branch pacing (LBB pacing) as an alternative to biventricular pacing in patients with symptomatic heart failure and an ECG with a typical left bundle branch block pattern.

Full description

Biventricular pacing has for more than a decade been standard of care for patients with HFrEF, LVEF < 35%, NYHA II-IV despite optimal medical treatment and an ECG with left bundle branch block (LBBB). However, it is not always ideal because of several drawbacks such as phrenic nerve capture, inability to reach late activated areas and many more. Direct HIS pacing can in many cases capture the left bundle and provide normal electrical activation of the left ventricle but sometimes with high pacing thresholds. Recently direct left bundle branch pacing has shown promise with synchronous activation of the left ventricle at low pacing thresholds.

In the present study the investigators randomize 125 patients in one center to either conventional CRT (45 patients) or HIS/LBB pacing (80 patients). In the HIS/LBB arm, direct HIS-pacing is attempted first but if its not possible or the pacing threshold for capturing the left bundle branch is > 2.5 V at 1 ms the investigators switch to placing a LBB-lead.

Power calculation for non-inferiority: With the 50 patients in the first His Alternative study (25 Biv-CRT og 25 His-CRT) the investigators observed a fall in systolic volumes of 34% and 46% with a standard deviation of 13-16%. Using these numbers it would take at least 108 patients to be 90% sure that the lower limit of a one-sided 97.5% confidence interval (equal to a 95% two-sided confidence interval) would be over the non-inferiority limit of -10%.

Enrollment

40 estimated patients

Sex

All

Ages

18+ years old

Volunteers

No Healthy Volunteers

Inclusion criteria

  • Patients over 18 years of age, ischemic or non-ischemic cardiomyopathy with LVEF ≤ 35% assessed by echocardiography, NYHA class II-IV heart failure symptoms despite optimal medical treatment and

    • Either planned new implantation of a biventricular pacing system (CRT-P or CRT-D), where the ECG is with sinus rhythm and a typical left bundle branch block (see definition below)
    • Or planned upgrade of an existing pacemaker or ICD to a biventricular pacing system (CRT-P or CRT-D), where the ECG is with sinus rhythm and a typical left bundle branch block or there has been> 90% right ventricular pacing from an existing pacemaker for at least 2 months prior to enrollment
  • Signed informed consent

  • Typical left bundle branch block:

    • QRS width > 130 msec for women and > 140 msec for men QS or rS pattern in leads V1 and V2, and mid-QRS plateau phase with or without extras in at least 2 of leads V1, V2, V5, V6, I, and aVL

Exclusion criteria

  • Existing biventricular pacing system
  • Permanent atrial fibrillation
  • Severe renal failure with eGFR < 30 ml/min
  • AMI or CABG within the last three months
  • The patient does not want to participate

Trial design

Primary purpose

Treatment

Allocation

Randomized

Interventional model

Parallel Assignment

Masking

Double Blind

40 participants in 2 patient groups

HIS/LBB pacing
Experimental group
Description:
In this arm a right ventricular (RV) lead or implantable cardioverter defibrillator (ICD) lead is placed first and then implantation of a HIS-pacing lead is attempted. If it is not possible to find and pace HIS, to correct the LBBB or the threshold for correcting the LBBB is \> 2.5 V at 1 ms, implantation of a LBB-pacing lead is attempted instead. If that is not possible either, a left ventricular (LV) lead is implanted. Intervention: Device: HIS/LBB pacing
Treatment:
Device: HIS/LBB pacing
LV pacing
Active Comparator group
Description:
In this arm an RV-lead or ICD-lead is placed first and then implantation of a LV-pacing lead is attempted. If this is not possible due to anatomical difficulties (no coronary sinus (CS) access, no available branches other than v cordis anterior or v cordis media) or electrical difficulties (no capture below 4 V at 1.0 msec or phrenic nerve stimulation \< 2x pacing threshold), implantation of a HIS-pacing lead is attempted instead. If that is not possible or the threshold for correcting the LBBB is \> 2.5 V at 1 ms, implantation of a LBB-pacing lead is attempted instead. Intervention: Device: LV pacing
Treatment:
Device: LV pacing

Trial contacts and locations

1

Loading...

Central trial contact

Daniel Keene, MBChB; mohamed zuhair, MBBS

Data sourced from clinicaltrials.gov