Status
Conditions
Treatments
About
The goal of this randomized, controlled, monocentric, single-blind, 2-arm, feasibility clinical investigation is to evaluate the safety of MectaShield hydrogel coating and to capture its preliminary clinical performance in the prevention of early peri-prosthetic joint infection (PJI) in patients undergoing cementless revision hip arthroplasty.
The main questions it aims to answer are:
Participants will undergo cementless revision hip arthroplasty; during surgery MectaShield hydrogel coating is applied on orthopaedic implants' surfaces (femoral stem and, if revised, acetabular cup) as a protective barrier for the prevention of bacterial adhesion. Surgery and follow-up are completed as per local standard practice. Stability will be assessed radiologically, while functional outcomes and PJI will be monitored by HOOS-PS, ASESPIS scores and according to the consensus document presented by European Society of Radiology (ESRa), the European Association of Nuclear Medicine (EANM), the European Bone and Joint Infection Society (EBJIS), and the European Society of Clinical Microbiology and Infectious Diseases (ESCMID). Researchers will compare the results of the treatment group with those from a control group receiving cementless revision hip arthroplasty without the application of MectaShiled hydrogel coating.
Full description
Peri-prosthetic joint infection (PJI) is among the first three reasons for joint replacement failure. PJI is a serious condition that may lead to repeated surgical interventions, prolonged hospitalization, high costs, and significant morbidity, although low mortality. To address this concern, antibacterial coating of implants has been proposed, as the adherence of the microorganisms to the implant, forming a biofilm, plays a strategic role in the pathogenesis of PJI. MectaShield (Medacta International SA) is a novel resorbable hydrogel coating intended to be spread on orthopaedic implants' surfaces as a protective barrier for the prevention of PJI. The study aims to evaluate the safety of MectaShield and to capture its preliminary clinical performance in the prevention of early PJI in patients undergoing cementless revision hip arthroplasty.
Patients suitable to receive MectaShield for cementless revision hip arthroplasty will be invited to take part to the study during the preoperative visit. Follow-up is performed after 3 and 12 months. Data collection includes clinical and functional data for preoperative and postoperative assessments, as well as intraoperative details, adverse events and device deficiencies. Patients will be randomized 1:1 in 2 groups:
The primary objective is to demonstrate that MectaShield hydrogel coating does not interfere with early primary stability at 3 months of follow-up
Secondary objectives are:
Enrollment
Sex
Ages
Volunteers
Inclusion criteria
Exclusion criteria
Primary purpose
Allocation
Interventional model
Masking
56 participants in 2 patient groups
Loading...
Central trial contact
Marco Viganó, PhD
Data sourced from clinicaltrials.gov