ClinicalTrials.Veeva

Menu

Hypoglycemia and Cardiac Arrhythmias in Type 1 Diabetes (Hypo-Heart-1)

S

Steno Diabetes Centers

Status

Completed

Conditions

Hypoglycemia
Arrhythmias, Cardiac
Diabetes type1

Treatments

Other: Hypoglycemic combined with either normo or hyperglycemic clamp.

Study type

Observational

Funder types

Other

Identifiers

NCT03956173
H-18034040

Details and patient eligibility

About

The investigators hypothesise that following episodes of hypoglycemia, rebound hyperglycemia may result in a prolonged period of increased QTc and, thereby, increased susceptibility to serious cardiac arrhythmias in patients with type - 1 diabetes.

Full description

In this study, changes in cardiac rhythm, haemodynamic regulation, and hormonal response will be evaluated during insulin-induced hypoglycemia followed by hyperglycemia and euglycemia, respectively, on two separate experimental days. Twenty-four patients with type-1 diabetes are included. Patients are randomised 1:1 to start with either the combined hypo- and hyperglycemic or the hypo- and euglycemic clamp. After an overnight 10 hour fast, participants are admitted for a 255 minute clamp. An individualised insulin infusion will be initiated targeting a plasma glucose level of 5.0-8.0 mmol/l. When the targeted plasma glucose level is achieved, the hyperinsulinemic euglycemic clamp will be initiated at time 0. The insulin infusion will be fixed at an infusion rate 80 mU/m2/min and a 20% glucose infusion will be initiated in order to regulate plasma glucose levels. After 45 min of monitoring at euglycemic plasma glucose level, plasma glucose will be decreased over a period of 30 minutes, targeting 2.5 mmol/l for a period of 60 min in a hyperinsulinemic hypoglycemic clamp. From 135 min to 195 min, plasma glucose levels will be increased to either hyperglycemic level or euglycemic level and will be kept constant for 105 minutes. Echocardiography is performed at baseline, at hypoglycemic level and at hyper-or normoglycemic level. Blood samples are taken every 15 minutes throughout the entire clamp, however bedside plasma glucose is analysed every fifth minute. A Holter-ECG is obtained throughout the entire clamp.

Enrollment

24 patients

Sex

All

Ages

18 to 80 years old

Volunteers

No Healthy Volunteers

Inclusion criteria

  • Informed and written consent
  • Type 1 diabetes diagnosed according to the criteria of the World Health Organization (WHO)
  • Age 18-70 years
  • Insulin treatment for ≥3 years

Exclusion criteria

  • Arrhythmia diagnosed prior to the screening visit
  • Implantable cardioverter defibrillator (ICD) or pacemaker at the time of inclusion
  • Severe heart failure (left ventricular ejection fraction <25%)
  • Structural heart disease (Wolf-Parkinson-White syndrome, congenital heart disease, severe valve disease)
  • Thyroid dysfunction (except for well-regulated eltroxin substituted myxoedema)
  • Anemia (male: hemoglobin <8.0; female: hemoglobin <7.0 mmol/l)

Trial design

24 participants in 1 patient group

Clamp group
Description:
24 patients with type 1 diabetes.
Treatment:
Other: Hypoglycemic combined with either normo or hyperglycemic clamp.

Trial contacts and locations

1

Loading...

Data sourced from clinicaltrials.gov

Clinical trials

Find clinical trialsTrials by location
© Copyright 2026 Veeva Systems