About

prospective randomized double-blind controlled study

Full description

Total of 69 ASA (American Society of Anesthesiologist) physical status class I or II patients will be enrolled.

Randomly assigned to three group according to the depth of guide-wire prior to tissue dilation during central catheterization via right internal jugular vein. (Group 1: 15 cm / Group 2: 17.5 cm / Group 3: 20 cm)

Central catheterization will be performed by anesthesiologists who be blinded to this study protocol.

An investigator will monitor and record whether any arrhythmia will occur.

The incidence of occurrence of arrhythmia will be compared between three groups.

Enrollment

69 patients

Sex

All

Ages

18+ years old

Volunteers

No Healthy Volunteers

Inclusion criteria

  • patients receiving general anesthesia requiring central venous catheterization via right internal jugular vein.
  • ASA (American Society of Anesthesiologist) physical status class I or II

Exclusion criteria

  • at the pre-anesthetic evaluation, history of any arrhythmia
  • when monitoring before the induction of anesthesia in the operating room, newly arrhythmia is observed.
  • abnormal electrolyte at the pre-anesthetic evaluation
  • too difficult to access right internal jugular vein for central catheterization (too short neck, infection at the site of right internal jugular vein, ventriculoperitoneal shunt or chemo-port existence at the site of right internal jugular vein. too close site to operating field)

Trial design

Primary purpose

Prevention

Allocation

Randomized

Interventional model

Parallel Assignment

Masking

Double Blind

69 participants in 3 patient groups

15 cm
Experimental group
Description:
The depth of guide wire will be 15 cm from puncture site of skin prior to tissue dilation during central venous catheterization
Treatment:
Device: central venous catheterization
17.5 cm
Experimental group
Description:
The depth of guide wire will be 17.5 cm from puncture site of skin prior to tissue dilation during central venous catheterization
Treatment:
Device: central venous catheterization
20 cm
Active Comparator group
Description:
The depth of guide wire will be 20 cm from puncture site of skin prior to tissue dilation during central venous catheterization
Treatment:
Device: central venous catheterization