ClinicalTrials.Veeva

Menu

ILM Peeling Versus Inverted Flap Technique for Treatment of Macular Hole: Near Visual Acuity Outcomes

F

Faculty Hospital Kralovske Vinohrady

Status

Enrolling

Conditions

Macular Holes

Treatments

Procedure: 25-gauge pars plana vitrectomy with complete internal limiting membrane peeling and SF6 tamponade
Procedure: 25-gauge pars plana vitrectomy with inverted flap technique and SF6 tamponade

Study type

Interventional

Funder types

Other

Identifiers

NCT04698226
MH SRD V1.0

Details and patient eligibility

About

A prospective randomised study comparing the near visual acuity outcomes using Salzburg Reading Desk in pseudophakic patients with idiopathic full-thickness macular hole treated with pars plana vitrectomy with internal limiting membrane peeling versus inverted flap technique. The aim of the study is confirm or disprove the hypothesis, that the near visual acuity results of pars plana vitrectomy with inverted flap technique for idiopathic macular hole are not inferior to pars plana vitrectomy with complete internal limiting membrane peeling technique. Patients will be followed for 6 months after the operation and near best corrected visual acuity testing on Salzburg reading desk, distance best corrected visual acuity on ETDRS tables and microperimetry will be performed and compared between both groups. Also the macular hole closure rate and complication rate will be compared between both groups.

Full description

Idiopathic full-thickness macular hole (MH) is an anatomic defect of the macula caused by the traction of the vitreous. Interruption of all neural retinal layers from the internal limiting membrane (ILM) to the retinal pigment epithelium (RPE) is present. Although other therapeutic approaches like pneumatic or enzymatic vitreolysis may lead to MH closure, pars plana vitrectomy (PPV) remains a gold standard for the treatment of full-thickness MH. Combination of PPV with full ILM peeling showed excellent results in small to medium MH, however the success rates dropped significantly with the increasing size of MH. PPV with inverted flap technique was introduced to address this issue and showed great results in MH of all diameters. In inverted flap technique, ILM is peeled around the MH and small piece of it is placed over the MH. It is speculated, that it serves as a scaffolding for gliosis allowing it to close large MHs. Besides gliosis, the ILM flap seals the MH by secluding communication between the vitreous and subretinal space, creating a closed compartment enabling the RPE to pump out fluid effectively. However, it is not known whether the ILM left in the macular hole might not hinder the healing process and full closure of macular hole. The aim of this study is to perform a detailed assessment of the state of the macula and near best corrected visual acuity and to compare the results of complete ILM peeling and ILM flap technique.

This is a prospective randomised study comparing the near visual acuity outcomes using Salzburg Reading Desk in pseudophakic patients with idiopathic full-thickness MH treated with PPV with ILM peeling versus inverted flap technique. Participants are randomized in a 1:1 ration to undergo 25-gauge PPV with complete ILM peeling or with circular inverted flap technique with sulphur hexafluoride as a tamponade and recommendation to maintain reading position for 3 days.

At baseline visit (D1) one day prior to the operation, patients undergo distance best corrected visual acuity (BCVA) exam using ETDRS charts, intraocular pressure (IOP) measuring using the non-contact tonometry, anterior segment slit-lamp examination, fundus biomicroscopy, microperimetry and optical coherence tomography (OCT).

At month 3 (M3) and month 6 (M6) visits, patients undergo distance BCVA exam using ETDRS charts, near BCVA exam using the Salzburg reading desk (SRD Vision, NY, USA), IOP measuring using the non-contact tonometry, anterior segment slit-lamp examination, fundus biomicroscopy, microperimetry, and OCT. The closure of macular hole and post-operational complications are assessed.

Distance BCVA is performed using ETDRS charts and recorded in logMAR.

Microperimetry is performed using the MAIA Confocal Microperimeter (CenterVue S.p.A, Padova, Italy). Expert exam 4-2 of the study eye is performed two times and the average of macular integrity score, average threshold score and fixation stability P1 and P2 are recorded.

OCT is performed using the Spectralis OCT (Heidelberg Engineering GmbH, Heidelberg, Germany). Macula of the study eye is scanned in 512 horizontal scans in the angle of 20x20 degrees with the spacing of 11 um in High Speed mode with noise reduction set to ART=5. The minimum and basal macular hole diameter is recorded, and the staging of the macular hole is performed using both the Gass and International Vitreomacular Traction Study Classification System. Presence or absence of epiretinal membrane is recorded.

Near BCVA is performed using the Salzburg reading desk. The best near correction is determined first using the Jaeger Reading Eye Charts. Examination on Salzburg reading desk is performed afterwards in Czech with the reading distance set to 40 cm with contrast and luminance set to 100%. Progressively smaller text is presented to the patient until his reading speed falls under 80 words per minute (wpm) or until his word miss rate is higher than 1. At this point, patient is presented with 5 different sentences with the same text size. Test is ended if the patient cannot exceed the reading speed of 80 wpm or if his word miss rate is higher than 1 3 or more times for the same text size. The smallest text size where reading speed is over 80 wpm or word miss rate is 1 or lower is recorded in logMAR as near BCVA.

Enrollment

60 estimated patients

Sex

All

Ages

18+ years old

Volunteers

No Healthy Volunteers

Inclusion criteria

  • Adult patients over 18 years of age
  • With idiopathic full thickness macular hole verified on OCT (Gass stage 2-4)
  • Minimal macular hole size under 1000 um
  • Pseudophakic

Exclusion criteria

  • Presence of other ocular pathology influencing visual acuity (e.g. age-related macular degeneration, diabetic retinopathy etc.)
  • Unwilling to sign the informed consent form
  • Unable to come to the study visits
  • Health status not allowing participation in the study

Trial design

Primary purpose

Treatment

Allocation

Randomized

Interventional model

Parallel Assignment

Masking

Single Blind

60 participants in 2 patient groups

ILM peel
Active Comparator group
Description:
Patients who will undergo 25-gauge pars plana vitrectomy with complete internal limiting membrane peeling and SF6 tamponade.
Treatment:
Procedure: 25-gauge pars plana vitrectomy with complete internal limiting membrane peeling and SF6 tamponade
Inverted flap
Experimental group
Description:
Patients who will undergo 25-gauge pars plana vitrectomy with inverted flap technique and SF6 tamponade.
Treatment:
Procedure: 25-gauge pars plana vitrectomy with inverted flap technique and SF6 tamponade

Trial contacts and locations

1

Loading...

Central trial contact

Martin Pencak, M.D.; Miroslav Veith, M.D.

Data sourced from clinicaltrials.gov

Clinical trials

Find clinical trialsTrials by location
© Copyright 2026 Veeva Systems