Imaging and Plan Workflow in a Novel Low-Field Magnetic Resonance Imaging (MRI) Radiotherapy Device

The Washington University logo

The Washington University

Status and phase

Terminated
Phase 1

Conditions

Malignant Tumor
Cancer

Treatments

Device: Magnetic resonance imaging

Study type

Interventional

Funder types

Other

Identifiers

NCT02331381
201311081

Details and patient eligibility

About

The results of this imaging and treatment planning protocol will aid in developing procedures for patient localization and future clinical implementation of low-field MRI to confirm positioning prior to radiation treatment. Images acquired during this study may aid future study design for adaptive planning based on low-field MRI images. Moreover, results of this imaging and treatment planning may lead to guidance on optimal use of this novel device.

Full description

Recently, Viewray Inc (Cleveland, OH) has released the RenaissanceTM System 1000, which consists of the combination of an open, split solenoid 0.35 T MRI scanner that is equipped for parallel imaging with a 60Co gamma-ray radiation treatment unit. The MRI scanner is required to be a low field unit to allow for imaging with spatial integrity by limiting magnetic susceptibility artifacts due to the patient and to prevent significant perturbations of the dose distribution. The 0.35 T magnet is a variant of the Siemens MAGNETOM product used for intraoperative imaging.

A previous study of pilot imaging using this device without the 60Co sources was completed in 2012 (HRPO# 201105295). In this study, a total of 26 patients were imaged with the device. Fourteen of these patients also had onboard CT imaging (OB-CT) where the two sets of imaging and relative organs at risk (OARs) could be compared. Fifteen to 24 OARs were evaluated per anatomical site. In total, 221 OARs and 10 target structures were compared for visualization on MRI and OB-CT image sets by each physician. At least 2/3 physicians evaluated MRI as offering better visualization for 71% of structures, OB-CT offering better visualization for 10% of structures, and both offering equivalent visualization for 14% of structures. Physicians agreed unanimously for 74% and in majority for >99% of structures evaluated, respectively. For <1% of structures, no consensus was reached. Targets were better visualized on MRI in 4/10 cases, and were never better visualized on OB-CT images.

There were limitations to this prior study. The patients were not imaged in immobilization devices that are commonly used in radiation therapy. This precluded the creation of a mock radiation therapy plan using the device for these patients. Also, the device was not evaluated in the context of radiation therapy decision making, such as patient shifts, target localization and patient repositioning.

The purpose of this study is to evaluate the imaging and plan workflow for radiation therapy utilizing this novel device. For this protocol, only the MRI scanner of the machine will be utilized. The 60Co portion of the machine capable of radiation treatment administration will not be utilized, and there will be no experimental treatments or modifications to each patient's standard of care radiation treatment plan.

Enrollment

15 patients

Sex

All

Ages

18+ years old

Volunteers

No Healthy Volunteers

Inclusion and exclusion criteria

Eligibility Criteria:

  • Scheduled to receive radiation therapy.
  • At least 18 years of age.
  • Does not meet any standard contraindications for MRI (such as being claustrophobic, having metal objects within the body that cannot be removed or having large tattoos), confirmed by completion of our clinical MRI questionnaire form
  • Able to understand and willing to sign an IRB approved written informed consent document.

Trial design

Primary purpose

Diagnostic

Allocation

N/A

Interventional model

Single Group Assignment

Masking

None (Open label)

15 participants in 1 patient group

MRI
Experimental group
Description:
Participants will have a custom immobilization device created for them for the purpose of the study. They will be scanned from one to four occasions during radiation treatment. If enrolled in the study prior to the first radiation treatment, the first imaging scan may be scheduled prior to the first radiation treatment, with subsequent scans during treatment separated by at least one day. Patients will be in the scanner for approximately 30 minutes to one hour, either prior to or following their standard of care radiotherapy treatment.
Treatment:
Device: Magnetic resonance imaging