ClinicalTrials.Veeva

Menu

Impact of Abutment Screw Torque on Marginal Bone Loss

U

University of Valencia

Status

Not yet enrolling

Conditions

PROMS According to the Abutment Torque
Soft Tissues According to the Abutment Torque
Marginal Bone Loss According to the Abutment Torque
Microleakage Accordint to the Abutment Torque

Treatments

Procedure: Abutment torqued to 15 Ncm
Procedure: 2 mm healing cap
Procedure: Pilar torqued to 30 Ncm

Study type

Interventional

Funder types

Other

Identifiers

NCT07234552
UV-INV_ETICA-3792382

Details and patient eligibility

About

The objective of this clinical trial is to evaluate the impact of different torque values applied during transmucosal abutment placement in dental implants on marginal bone loss and peri-implant parameters, including the patient's perception of the treatment.

The main questions the study aims to answer are:

  1. Is there any difference in marginal bone loss between abutments torqued at 15 Ncm, 30 Ncm, and submerged implants without immediate transmucosal connection?
  2. Are there differences in microleakage between the different torque levels?
  3. How do these torque values affect peri-implant soft tissues and patient satisfaction?
  4. Does the applied torque influence the patient's quality of life after the prosthetic phase?

Each participant will receive three dental implants during the same surgical procedure. One of the following approaches will be applied to each implant:

  1. A transmucosal abutment torqued to 15 Ncm
  2. A transmucosal abutment torqued to 30 Ncm
  3. A healing cap without transmucosal connection (submerged implant)

After implant placement, clinical and radiographic assessments will be performed to measure marginal bone loss and peri-implant parameters.

Full description

This study aims to analyze how different torque levels applied during transmucosal abutment placement on dental implants influence peri-implant tissue health and other relevant clinical parameters. A randomized clinical trial will be conducted in which each participant will receive three dental implants. Each implant will be assigned to one of the following conditions: an abutment torqued to 15 Ncm, an abutment torqued to 30 Ncm, and a submerged implant with a healing cap, without immediate transmucosal connection.

This intra-individual design enables direct comparison of outcomes while minimizing inter-individual variability that could affect the results.

Throughout the treatment process, various data will be collected. During surgery, patient-reported comfort levels will be recorded. Following prosthesis placement, standard clinical measurements will be performed, including peri-implant probing, bleeding on probing, inflammation, and radiographic evaluation of marginal bone loss.

Additionally, patient-reported outcomes during the first week after the initiation of the prosthetic phase will be documented, including pain levels, inflammation, and analgesic use. Overall satisfaction and the impact of treatment on quality of life will also be assessed using a Likert-type scale, focusing on functions such as chewing, speech, sleep, and daily activities.

The goal of this study is to determine whether the torque applied during abutment connection has a clinically relevant effect on both peri-implant tissue response and patient perception of the treatment. The findings may contribute to improved clinical guidelines in implant dentistry and enhance long-term treatment outcomes.

The study protocol has been approved by the relevant ethics committee and will comply with all applicable clinical research regulations. All participants will provide written informed consent prior to enrollment.

Enrollment

30 estimated patients

Sex

All

Ages

18+ years old

Volunteers

Accepts Healthy Volunteers

Inclusion criteria

  • Posterior edentulism
  • Completion of craniofacial growth
  • Full-mouth plaque index and bleeding index < 25%
  • Sufficient bone height and width for implant placement without the need for bone regeneration procedures
  • Presence of at least 2 mm of keratinized mucosa around the dental implant
  • Stable occlusion and healthy periodontium
  • Absence of medical conditions that contraindicate implant surgery, such as heavy smoking (<10 cigarettes per day), severe bruxism, pregnancy or breastfeeding, bisphosphonate therapy, and patients undergoing chemotherapy or radiotherapy in the head and/or neck area
  • Uncooperative patients

Exclusion criteria

  • Loss to follow-up
  • Incorrectly parallelized periapical radiographs

Trial design

Primary purpose

Treatment

Allocation

Randomized

Interventional model

Parallel Assignment

Masking

Triple Blind

30 participants in 3 patient groups

Transmucosal Abutment - 15 Ncm
Experimental group
Treatment:
Procedure: Abutment torqued to 15 Ncm
Transmucosal Abutment - 30 Ncm
Experimental group
Treatment:
Procedure: Pilar torqued to 30 Ncm
Submerged Healing Cap (No Transmucosal Connection)
Experimental group
Treatment:
Procedure: 2 mm healing cap

Trial contacts and locations

0

Loading...

Central trial contact

Juan Carlos Bernabeu Mira

Data sourced from clinicaltrials.gov

Clinical trials

Find clinical trialsTrials by location
© Copyright 2026 Veeva Systems