The purpose of this study is to evaluate the safety and performance of the EYEMATE system in patients undergoing concomitant implantation of a BKPro type 1 and an EYEMATE sensor over the 24 months period beginning at implantation.
Full description
The purpose of this study is to evaluate the safety and performance of the EYEMATE system in patients undergoing concomitant implantation of a BKPro type 1 and an EYEMATE sensor over the 24 months period beginning at implantation. The EYEMATE system involves an EYEMATE implantable sensor working together with a MESOGRAPH hand-held reading device. The aim of this investigation is to collect intraocular pressure data with the EYEMATE pressure sensor in patients with BKPRO type and determine the relationship between the following glaucoma characteristics: intraocular pressure, characteristics and evolution of the optic nerve, visual fields, and OCT of the optic nerve. The intraocular pressure will be measured by three means. First, there will be mapping of the diurnal fluctuation of IOP with daily IOP self-measurement profiles with the EYEMATE system (subjects). Secondly, there will be mapping of fluctuation of IOP measurements with the EYEMATE system (site staff). Thirdly, the IOP will be evaluated through the measurement of the Schiotz tonometer on the limbal conjunctiva.
The primary performance objective is to collect IOP data with the EYEMATE system and compare the level of agreement between IOP measurements made using schiotz tonometry and the EYEMATE system over the first 24 months following implantation. The secondary performance objective is to determine the relationship between the IOP data with the use of the EYEMATE system and the progression of glaucoma through the evaluation of the characteristics of the optic nerve, visual fields, and OCT of the peripapillary retinal nerve fiber layers in patients with BKPRO type 1. The secondary safety objective is to evaluate the safety and tolerability of the EYEMATE pressure sensor, record adverse effects and incidence of device deficiencies in the first 24 months through the recording of incidence, nature, seriousness, severity and duration of adverse events at day 1 and at months 1, 4, 8, 12, 16, 20, 24 following implantation of the EYEMATE pressure sensor.
Sex
Ages
Volunteers
Inclusion criteria
Exclusion criteria
Primary purpose
Allocation
Interventional model
Masking
0 participants in 2 patient groups
Loading...
Data sourced from clinicaltrials.gov
Clinical trials
Research sites
Resources
Legal