In Vivo Comparison of Two Different Occlusal Splints in Bruxism

M

Marmara University

Status

Completed

Conditions

Bruxism

Treatments

Device: Stabilization splint

Study type

Interventional

Funder types

Other

Identifiers

NCT06482060
MUDHF_Prosthesis_01

Details and patient eligibility

About

According to the international consensus, bruxism is a masticatory muscle activity consisting of grinding and clenching while sleep or wakefullness. The etiology of bruxism is multifactorial and phisical and psychological facts are some causes of this habit. Bruxism is one of the main causes of tooth wear and temporomandibular joint diseases. Muscle ensembles that occur in bruxist individuals can cause temporomandibular joint degenerations. There is no definitive method recommended for the treatment of sleep bruxism. The most important clinical intervention for sleep bruxism is to protect teeth, reduce teeth grinding, relieve facial and temporal pain and improve sleep quality.

Stabilization splint is the gold standard in temporomandibular joint treatments. The purpose of occlusal splint treatment is to improve the functions of tmj and masticatory muscles by creating a balanced , stable occlusion to eliminate the associated pain to reduce the effects of occlusal interferences and parafunctional habits. Conventional occlusal devices have been fabricated from different materials including polyethylene (PVAc-PE), auto-, heat-, and lightpolymerized acrylic resin. However, despite the interesting characteristics of these materials, they are not considered optimal due to potential thermal discomfort, bad taste, residual monomers, dimensional instability, undesirable shape or color, fracture susceptibility, and skin or respiratory allergies of polymethyl mehacrylate (PMMA) resin, in addition to the time-demanding manufacturing process. New digital technologies based on computer-aided design and computer-aided manufacturing have enabled the use of digital workflow in the fabrication of occlusal devices or other intraoral prostheses such as complete dentures and interim fixed restorations, by using subtractive milling or additive approaches. Such devices are manufactured from prefabricated and standard materials such as polycarbonate, polyetheretherketone (PEEK), and PMMA discs. The whole workflow of digital occlusal splints enhances occlusal design and considerably simplifies and optimizes the traditional occlusal splint manufacturing process. Furthermore, digital occlusal splints have shown superior performance over traditional ones in terms of fit, quantitative control, time-saving, speed, and dimensional stability.

The aim of this study is to evaluate the patient satisfaction and wear rates of occlusal splint materials that fabricated with conventional and CAD/CAM techniques.

Full description

The patients who applied to Marmara University Faculty of Dentistry Department of Prosthodontics with complaints of teeth clenching and grinding were clinically and radiologically examined. A questionarre is also applied to evaluate the sleep bruxism. 30 individuals diagnosed with sleep bruxism were included in this study. The individuals were informed about bruxism, its effects and the application of a stabilization splint and were divided into two groups randomly. Stabilization splint was applied to one group with digital and to other group with conventional impression and production method.

In the conventional treatment group, impressions were taken with alginate impression material, then the occlusal splint was fabricated with hard vinyl resin material in the dental laboratory. The splints were appllied o the upper jaw in accordance with the recomendations of Okeson. Canine guidence was provided in lateral movements. Autopolymerizing acrylic (Imıcryl, Turkey) was used for the adjustment of the splint intraorally. The individuals were asked to come for monthly recalls according to the routine treatment procedure and the pain values measured by visual analog scale (VAS). The occlusal surfaces of the stabilization splints were scanned before the usage of splint and after the three and six months usage. The wear amounts were calculated by Geomagic Control Program for evaluation. Patient satisfaction was evaluated with the questionarre at the beginning and final stage of the treatment.

In the CAD/CAM treatment group, intraoral digital impressions were taken with an intraoral camera (3Shape Trios (3Shape Dental Systems, Copenhagen, Denmark)) and the occlusal splints were fabricated with methacrylate resin material by digital three dimensional production. The splints were delivered to the individuals. Minimal occlusal adjustment was performed to obtain canine guidence. The individuals were asked to come for monthly recalls according to the routine treatment procedure and the pain values measured by visual analog scale (VAS). The occlusal surfaces of the stabilization splints were scanned before the usage of splint and after the three and six months usage. The wear amounts were calculated by Geomagic Control Program for evaluation. Patient satisfaction was evaluated with the questionarre at the beginning and final stage of the treatment.

Enrollment

30 patients

Sex

All

Ages

18 to 60 years old

Volunteers

Accepts Healthy Volunteers

Inclusion criteria

  • Volunteers with natural dentition between the ages of 18-60
  • Diagnosed with bruxism

Exclusion criteria

  • Pregnancy
  • Alcohol or drug addiction
  • Having more than one missing tooth in one part of the oral arch

Trial design

Primary purpose

Treatment

Allocation

Randomized

Interventional model

Parallel Assignment

Masking

None (Open label)

30 participants in 2 patient groups

Conventional group
Active Comparator group
Treatment:
Device: Stabilization splint
Digital workflow group
Experimental group
Treatment:
Device: Stabilization splint