Status
Conditions
Treatments
About
Hypercapnea is a condition where there is too much carbon dioxide (CO2) in the blood. Carbon dioxide is a gaseous product of the body's metabolism and is normally expelled through the lungs (breathed out). Hypoventilation (or respiratory depression) occurs when the ventilation is inadequate to perform needed gas exchange; therefore resulting in decreased levels of oxygen and increased levels of carbon dioxide in the blood. It can cause an increased concentration of carbon dioxide and respiratory acidosis. Obesity is a multi-system disorder, particularly involving the respiratory (lungs/breathing) and cardiovascular (heart/vessel) systems. Obesity increases the risks for surgical and anesthetic complications before, during and following surgery.
Bariatric (weight loss) surgery is becoming a common procedure among the morbidly obese (100 lbs or more above normal weight), with recent studies highlighting the long-term health implications of surgical weight reduction, to include a decreased risk of hypertension (high blood pressure) and diabetes (increased sugar in blood). Obese patients are at increased risk of sleep apnea (stop breathing while asleep) and hypoventilation even without surgery, and these risks increase following administration of medications typically given during and after major surgical procedures. Hypoventilation can lead to hypercapnea, sedation (sleepiness), and acidosis (blood imbalance), resulting in further respiratory compromise (breathing problems) and cardiac morbidity (heart problems) as well as the risks inherent in re-intubating (needing to have a breathing tube place down into the lungs) the obese.Monitoring for hypoventilation can be difficult. Quantitative capnography (measuring carbon dioxide) is only appropriate for intubated patients (on a ventilator - breathing tube), and pulse oximetry (clip on finger that measures oxygen levels) does not adequately detect hypoventilation in patients receiving supplemental (additional) oxygen. Serial arterial blood gas (blood taken from an artery to measure oxygen level in blood) measurement is expensive, time-consuming, and painful. Continuous respiratory rate monitoring is possible, and has been considered the gold standard of apnea detection (seeing stopped breathing), yet is seldom used. As a result of these limitations, there is currently no simple, cost-effective, and reliable means of detecting hypoventilation in this patient population either in the recovery room or inpatient unit. Transcutaneous (across the skin) pCO2 (t-pCO2) monitoring has been validated as a reliable and reproducible means of measuring pCO2 in newborn babies, and recently has also been used in adults, primarily in the ICU (intensive care unit) setting. When compared to standard end-tidal CO2 measurement, t-pCO2 correlates better with pCO2 in the intraoperative period in both thin and obese patients. SenTec, is the manufacturer of a device used to measure t-pCO2 for this project. This study is designed to detect the incidence of hypercapnea in morbidly obese post-surgical bariatric patients in the postoperative period using the SenTec t-pCO2 monitor.
Objective:To determine the incidence of hypoventilation and hypercapnea as measured by transcutaneous pCO2 monitoring in post-surgical bariatric patients as compared to thin controls.
Enrollment
Sex
Ages
Volunteers
Inclusion criteria
Exclusion criteria
22 participants in 2 patient groups
Loading...
Data sourced from clinicaltrials.gov
Clinical trials
Research sites
Resources
Legal