ClinicalTrials.Veeva

Menu

Influence of Original Native Tricuspid Valve Lesion (Stenosis or Steno-insufficiency or Insufficiency) on Post-implant Structural Bioprosthetic Degeneration After Tricuspid Valve Replacement. (DURABLE-TRIC)

Maastricht University Medical Centre (MUMC) logo

Maastricht University Medical Centre (MUMC)

Status

Invitation-only

Conditions

Degeneration of Tricuspid Surgical Bioprosthesis

Treatments

Procedure: Valve replacement

Study type

Observational

Funder types

Other

Identifiers

NCT06875154
2023-0324

Details and patient eligibility

About

The structural deterioration process of the implanted bioprosthesis in tricuspid position for tricuspid valve pathology is gradual and irreversible and includes many changes, such as pannus growth, leaflet fibrosis and calcification, delamination of the connective tissue, ruptures and perforations of leaflets. In the great majority of cases SVD consists of leaflet calcium deposits and can be clinically associated with young age, hypercholesterolemia, hypertension, diabetes mellitus, renal failure. The long term durability of these bioprosthesis is still missing.

Full description

It is not clear if the same biochemical, hemodynamic and immunological mechanisms leading to native valve calcification can cause bioprosthetic SVD. We hypothesize that the mechanisms protecting the native valve from calcification in the insufficiency disease may subsequently protect also the bioprosthetic valve from calcific SVD. In such a case, considering also the reduced incidence in insufficiency patients of prosthesis-patient mismatch, supposedly associated with increased risk of SVD, indication for bioprosthetic valve use could be expanded in patients with insufficiency. Because of the rising demand of bioprosthetic valve implantation, even a few years increase in the expected durability of the BHV, although limited to a defined population of patients, will have a very relevant clinical impact.

We aim to perform a retrospective, multi-center, observational study. All patients undergoing elective tricuspid valve replacement from 2000 to 2020 who met the inclusion criteria for the study (described in the dedicated section) will be enrolled in the study. These patients will be followed-up as part of routine care, and information about the clinical status, NYHA functional class, possible rehospitalization, possible cardiovascular events and postoperative echocardiography will be available for analysis. Once consent is given, and if required by local governance, pre-, intra- and post-operative data will be collected in a dedicated, structured, database.

Enrollment

500 estimated patients

Sex

All

Ages

18+ years old

Volunteers

No Healthy Volunteers

Inclusion criteria

  • Age ≥ 18 years; 6

  • Patients who underwent isolated tricuspid valve replacement for stenosis, regurgitation or steno-regurgitation

  • Signed informed consent, inclusive of release of medical information where required by local governance.

Exclusion criteria

  • Tricuspid valve replacement associated with other surgical procedures (CABG or other)

Previous cardiac surgery of any kind;

  • Surgery for acute endocarditis

  • Participation in another clinical trial that could interfere with the endpoints of this study.

  • Pregnant or breastfeeding at time of screening.

Trial design

500 participants in 1 patient group

Surgical Tricuspid bioprosthesis
Description:
All patients undergoing elective tricuspid valve replacement from 2000 to 2020. All operations were performed through median longitudinal sternotomy, mini-sternotomy or mini- thoracotomy.Intraoperative transesophageal echocardiography (TOE) was used in all patients. Arterial cannulation was central and venous cannulation was achieved with a common two-stage cannula in the right atrium. Left ventricle was vented through the right superior pulmonary vein.In minimally invasive procedures, venous cannulation was achieved percutaneously. Myocardial protection was achieved by administration of cold crystalloid or blood cardioplegia at the surgeon's discretion in an antegrade (indirect or selective) or retrograde fashion. Beating heart procedure can be performed without the use of aortic clamp. The prosthesis were be implanted with 2-0 U-shaped sutures.
Treatment:
Procedure: Valve replacement

Trial contacts and locations

1

Loading...

Data sourced from clinicaltrials.gov

Clinical trials

Find clinical trialsTrials by location
© Copyright 2026 Veeva Systems