Integrated Imaging System for In Vivo Visualization of Free Flap Perfusion Using Indocyanine Dye

Case Comprehensive Cancer Center (Case CCC) logo

Case Comprehensive Cancer Center (Case CCC)

Status

Suspended

Conditions

Breast Reconstruction

Treatments

Device: SmartGoggles

Study type

Interventional

Funder types

Other

Identifiers

NCT03625765
CASE2118

Details and patient eligibility

About

The purpose of this study is to determine if the integrated imaging goggle (Smart Goggles) is as good as or better than current technology used to assess tissue perfusion (the extent of blood flow to the tissue) in certain types of breast reconstruction procedures.

The participants will be asked to participate in the study if they are scheduled to have a breast reconstruction procedure using a technique that involves transferring abdominal skin and tissues to the affected side of the chest. This technique is known as a breast reconstruction with a Deep Inferior Epigastric Artery Perforator (DIEP) flap.

In this pilot study, the investigators are testing the feasibility of a new device, the Integrated Imaging Goggle system (also called "Smart Goggles") as a surgical aid to differentiate between tissue with adequate blood flow and tissue without adequate blood flow by comparing measurements of fluorescence in blood vessels with current technology, the SPY-Elite system. In this study, researchers will test how quickly and accurately the fluorescent dye used to identify adequate blood flow is detected by Smart Goggles compared to the SPY Elite system.

Full description

The objective is to demonstrate the sensitivity of the SmartGoggles for detection of Indocyanine (ICG) fluorescence within fasciocutaneous flap. The investigators will characterize the sensitivity of the SmartGoggles device relative to a previously validated device (the SPY Elite system).

The investigator's primary endpoint will compare the ICG transit time (the time needed for ICG to first appear in flap after intravenous injection) detected by the SmartGoggles and the SPY Elite system.

As a secondary endpoint, the investigators will compare the ICG accumulation curve and fluorescence intensity generated from each device, measured on the same region of interests (ROI). Finally, the study team will compare perfusion margin characteristics (the area between regions of well-perfused and hypoperfused tissue) as assessed by the Goggles and the SPY Elite system.

Study Design This is an unpowered pilot study to determine the sensitivity of the new SmartGoggles device for detection of ICG fluorescence in free flaps in a clinical setting. The investigators have chosen to examine ICG as the contrast agent because this agent is FDA-approved and is regularly used for evaluation of tissue perfusion. The team has chosen to use DIEP free flaps as the clinical target because these flaps are relatively large and will provide adequate surface area for measurement of fluorescent margins and comparison of fluorescence between the Goggles and SPY Elite systems.

This study will enroll 25 patients. After signing consent form all patients will undergo standard of care preoperative and postoperative evaluations. Investigators will perform one ICG angiography per patient: intraoperatively after designing and harvesting the flap. All measurements will be taken by SmartGoggles and SPY Elite systems.

Enrollment

25 estimated patients

Sex

Female

Ages

18+ years old

Volunteers

No Healthy Volunteers

Inclusion criteria

  • Patients undergoing unilateral DIEP flap breast reconstruction
  • Subjects must have the ability to understand and the willingness to sign a written informed consent document.

Exclusion criteria

  • Pregnant women
  • Patients with severe hepatic insufficiency
  • Patients with a history of allergic reactions or know hypersensitivity to ICG and iodide

Trial design

Primary purpose

Supportive Care

Allocation

N/A

Interventional model

Single Group Assignment

Masking

None (Open label)

25 participants in 1 patient group

SmartGoggles
Experimental group
Description:
The prototype system offers real time stereoscopic fluorescence imaging along with in vivo handheld microscopy. Investigators have found that the system can detect fluorescent targets with as low as 1.2 picomoles ICG (60 nanomolar (nM) concentration). The hand-held microscopy module has a resolution of 25 micron. The prototype system has 2 complementary metal-oxide-semiconductor (CMOS) imaging sensors housed on a printed circuit board (PCB) with imaging lenses and emission filters optimized for ICG dye. The light source provides concurrent excitation centered at 780 nm and white light illumination with optical density (OD) 6 level cut-off. The SmartGoggles is a non-invasive imaging system that does not require contact with patients.
Treatment:
Device: SmartGoggles