INTELLiVENT-ASV Using Mainstream Versus Sidestream End-Tidal CO2 Monitoring (INTELLiSTREAM)

A

Academisch Medisch Centrum - Universiteit van Amsterdam (AMC-UvA)

Status

Completed

Conditions

Mechanical Ventilation Complication
Postoperative Care
Intensive Care Unit

Treatments

Device: Sidestream capnography using the 'Respironics LoFlo Sidestream CO2 Module'
Device: Mainstream capnography using the 'Respironics Capnostat 5 Mainstream CO2 sensor'

Study type

Interventional

Funder types

Other

Identifiers

NCT04599491
INTELLiSTREAM

Details and patient eligibility

About

Background

INTELLiVENT-ASV, an automated closed-loop mode of mechanical ventilation, available on Hamilton ventilators for clinical use, uses mainstream end-tidal CO2 (etCO2) monitoring to adjust minute ventilation. However, sensors for mainstream etCO2 monitoring are expensive and fragile. The less expensive and more robust sensors for sidestream etCO2 monitoring could serve as a good alternative to sensors for mainstream etCO2 monitoring.

Objective of the study

The objective of this randomized noninferiority trial is to determine whether INTELLiVENT- ASV with sidestream capnography is noninferior to INTELLiVENT-ASV with mainstream capnography with regard to the percentage of breaths in a broadly accepted predefined 'optimal' zone of ventilation.

Hypothesis

The investigators hypothesize that INTELLiVENT-ASV with sidestream capnography is noninferior to INTELLiVENT-ASV with mainstream capnography with respect to the percentage of breaths a patient spends within the 'optimal' zone of ventilation.

Study design

INTELLiSTREAM is a randomized noninferiority study.

Study population

The study population consists of consecutive elective cardiac surgery patients who are expected to need at least 2 hours of postoperative ventilation in the ICU of Amsterdam Medical University Centers, location 'AMC'.

Intervention

Shortly after arrival at the ICU, patients will be randomized to receive either ventilation with INTELLiVENT-ASV with mainstream capnography or sidestream capnography.

Primary outcome of the study

The primary study endpoint is the percentage of breaths a patient spends inside the 'optimal' zone of ventilation, as defined before (i.e. tidal volume < 10 ml/kg PBW, maximum airway pressure < 30cm H2O, etCO2 between 30-46 mmHg and pulse oximetry between 93-98%).

Secondary outcomes

The percentage of time spent in other ventilation zones, as defined in the protocol. Time to spontaneous breathing, duration of weaning, loss of etCO2 signal, duration of postoperative ventilation and ventilator parameters as well as results of clinically indicated arterial blood gas analysis.

Nature and extent of burden and risks associated with participation, benefit and group relatedness Hamilton ventilators can use mainstream and sidestream etCO2 sensors. INTELLiVENT-ASV is a safe mode of ventilation, also in patients who receive postoperative ventilation. Furthermore, as all patients are sedated as part of standard care during postoperative ventilation, the burden for the patient is minimal

Enrollment

72 patients

Sex

All

Ages

18 to 100 years old

Volunteers

No Healthy Volunteers

Inclusion criteria

  • Undergoing elective cardiac surgery in the Amsterdam University Medical Centers, location 'AMC'
  • Planned admission to the ICU for postoperative ventilation
  • Expected to need postoperative ventilation for at least 2 hours

Exclusion criteria

  • Age under 18 years
  • Patients previously included in the current clinical trial
  • Patients participation in other interventional clinical trials that could influence ventilator settings and ventilation parameters
  • Patients with suspected or confirmed pregnancy
  • Moribund patients

Trial design

Primary purpose

Supportive Care

Allocation

Randomized

Interventional model

Parallel Assignment

Masking

Single Blind

72 participants in 2 patient groups

INTELLiVENT-ASV with sidestream capnography
Experimental group
Description:
Patients randomized into the 'Sidestream capnography'-arm will receive postoperative ventilation on the ICU with INTELLiVENT-ASV with sidestream etCO2 monitoring.
Treatment:
Device: Sidestream capnography using the 'Respironics LoFlo Sidestream CO2 Module'
INTELLiVENT-ASV with mainstream capnography
Active Comparator group
Description:
Patients randomized into the 'Mainstream capnography'-arm will receive postoperative ventilation on the ICU with INTELLiVENT-ASV with mainstream etCO2 monitoring.
Treatment:
Device: Mainstream capnography using the 'Respironics Capnostat 5 Mainstream CO2 sensor'