ClinicalTrials.Veeva

Menu

Interferential Current And Trapezius Myofascial Trigger Points

Cairo University (CU) logo

Cairo University (CU)

Status

Completed

Conditions

Upper Trapezius Trigger Points

Treatments

Device: Interferential current with carrier frequency 2 KHz
Other: Stander treatment
Device: Interferential current with carrier frequency 8 KHz
Device: placebo interferential current
Device: Interferential current with carrier frequency 4 KHz

Study type

Interventional

Funder types

Other

Identifiers

NCT05275634
P.T.REC/012/003591

Details and patient eligibility

About

To investigate the effect of different carrier frequencies of interferential current on pressure pain threshold, neck disability, cervical range of motion and upper trapezius muscle activity when applied on upper trapezius chronic myofascial trigger points: Randomized Controlled Trial

Full description

Interferential current (IFC) is a medium frequency current derived from the interference of two symmetrical, but asynchronous alternating currents ranged from 1 to 10 KHz. The two main currents resulting in a single interference current with properties uniquely different from the two original currents.The lesser current of the two original currents is termed the carrier frequency and the interference current is called the beat frequency. A specific beat frequency can be obtained from several possible interference currents as long as the difference between the original currents is the same. For electro pain modulation, IFC is commonly used form of electrotherapy. It has the advantage of reducing the skin impedance, deeper penetration into tissues and is perceived as more comfortable.

Myofascial pain syndrome (MPS) is a common form of chronic musculoskeletal pain that widely spread and contributing to a significant financial burden and job- related disability. It represents the most common disorder in patients with nonspecific chronic neck pain.The main characteristics of MPS include the presence of myofascial trigger points (MTrPs) which are defined as hyperirritable nodule in a taut band of skeletal muscle fibers which is palpable and tender during physical examination. Trigger points (TrPs) are usually seen in the upper fiber of trapezius. TrPs can be clinically classified as either active or latent. Active TrPs was defined as: MTrPs that refer pain during activity and during rest without any pressure. They prevent full muscle lengthening and induce their weakness. Latent TrPs was defined as: MTrPs that is painful only when palpated. Evidence on the effect of IFC on pain modulation is not confirmed up till now. This might be attributed to multiple factors such as limited number of studies, inappropriate use of the parameters or using single carrier frequency (4 KHz) in majority of studies and the physiological effects of all our modalities are dose dependent. Dose depends on details of parameters including frequency. For IFC, the carrier frequency of the current has been suggested as an important parameter to achieve the most effective hypoalgesic response. However, there remains no evidence to support the selection of one carrier frequency over another. Few studies were conducted to examine the effect of different carrier frequencies by comparing their individual effects. Further researches are needed to prove which carrier frequency is more effective in treatment. Therefore, this study will be conducted to compare the effect of different carrier frequencies of the IFC in the management of upper trapezius chronic TrPs.

Enrollment

68 patients

Sex

All

Ages

18 to 29 years old

Volunteers

No Healthy Volunteers

Inclusion criteria

  • Ages from18-29 years old with unilateral chronic myofascial trigger points in upper trapezius muscle will be included in this study.
  • Participants have chronic myofascial trigger points if they have pain with pressure, local twitch response, jump sign, limited range of motion and referred pain lies over the lateral aspect of the upper trapezius fibers and superiorly to the ipsilateral occiput.
  • Normal body mass index (BMI) from 18-24.9 Kg/m (BMI = body mass in kg divided by participant height in meters).

Exclusion criteria

  • Onset of pain less than 3 months
  • History of whiplash injury
  • History of cervical spine surgery
  • Cervical radiculopathy or myelopathy and cervical disc lesion
  • Cervical spondylolisthesis
  • Having multiple sclerosis, thyroid dysfunction and chronic infection
  • Having rheumatologic condition as poly articular osteoarthritis, rheumatoid arthritis and advanced cervical spine degenerative diseases
  • Skin disease and impaired sensation
  • Phobia of using electrical current
  • Pregnancy, tumor, thrombosis and pacemaker
  • Administration of regular analgesic drugs or any medications that affect skin sensation.
  • Receiving physical therapy intervention during the past three months.

Trial design

Primary purpose

Treatment

Allocation

Randomized

Interventional model

Parallel Assignment

Masking

Double Blind

68 participants in 4 patient groups, including a placebo group

Standard treatment and interferential current with carrier frequency 2 KHz
Experimental group
Description:
Standard treatment and interferential current with carrier frequency 2 KHz will be received three times a week for four weeks.
Treatment:
Other: Stander treatment
Device: Interferential current with carrier frequency 2 KHz
Standard treatment and interferential current with carrier frequency 4 KHz
Experimental group
Description:
Standard treatment and interferential current with carrier frequency 4 KHz will be received three times a week for four weeks.
Treatment:
Other: Stander treatment
Device: Interferential current with carrier frequency 4 KHz
Standard treatment and interferential current with carrier frequency 8 KHz
Experimental group
Description:
Standard treatment and interferential current with carrier frequency 8 KHz will be received three times a week for four weeks.
Treatment:
Other: Stander treatment
Device: Interferential current with carrier frequency 8 KHz
Standard treatment and placebo interferential current
Placebo Comparator group
Description:
Standard treatment and placebo interferential current will be received three times a week for four weeks.
Treatment:
Other: Stander treatment
Device: placebo interferential current