ClinicalTrials.Veeva

Menu

Intramedullary Devices for the Treatment of Unstable Pertrochanteric Fractures

Medical University of Vienna logo

Medical University of Vienna

Status

Completed

Conditions

Fractures

Treatments

Device: PFNA
Device: Gamma Nail 3

Study type

Interventional

Funder types

Other

Identifiers

NCT02074969
2007406

Details and patient eligibility

About

The purpose of this study is to assess the differences between two different types of devices for the treatment of unstable pertrochanteric hip fractures. The hypothesis of this study is, that patients who are treated with the proximal femoral Nail Antirotation (PFNA) have a better outcome and lower complication rates than patients treated with the Gamma Nail (GN3).

Full description

This trial is a prospective randomized controlled study including the treatment of AO/OTA 31-A2 fractures in 200 patients with 2 different surgical devices. 100 patients are treated with a Gamma Nail 3 (GN3) (Stryker) the other 100 patients with a Proximal Femoral Nail Antirotation (PFNA) (Synthes).

All surgeries are performed by trauma surgeons at a Level 1 University Hospital. One hundred patients are randomized to the gamma nail and 100 are randomized to the proximal femoral nail for treatment fixation. A 1:1 randomization is performed using sealed envelopes (200 in total), which are opened by the surgeon immediately before the operation.

Patients missing an informed consent form, incomplete chart, or showing a pathologic fracture are getting excluded from final comparisons.

Patients anthropometric data as well as pre-injury mobility assessments, and ASA will be documented. Furthermore the time from admission to going to surgery, surgery length, length of stay and mobility assessment at dischargement are recorded.

After surgery the stay in the hospital is documented precisely and patients are scheduled for next appointments 2 weeks, 6 weeks, 3 months, 6 months and 1 year after surgery.

Postoperative X-rays are measured precisely to determine the Tip-Apex Distance (TAD), the Parkers-Ratio, the Singh-Score and the Neck-Shaft-Angle of the injured and contralateral side. Rates of complications as cut-out and reoperation-rates are evaluated. All intra-operative complications are noted and included in the chart.

Enrollment

200 patients

Sex

All

Ages

18+ years old

Volunteers

Accepts Healthy Volunteers

Inclusion criteria

  • AO/OTA 31-A2 fractures
  • age between 18 - 100 years
  • Signed written informed consent and agreement to attend the planned FUs
  • Able to understand and read country national language at an elementary level

Exclusion criteria

  • missing informed consent form
  • pathological fracture
  • incomplete patient record
  • death within one month of intervention (surgery)
  • prior surgery to the hip
  • polytrauma
  • any additional fracture
  • any implant at the same hip
  • infection

Trial design

Primary purpose

Treatment

Allocation

Randomized

Interventional model

Parallel Assignment

Masking

None (Open label)

200 participants in 2 patient groups

Gamma Nail 3
Active Comparator group
Description:
Gamma Nail 3 Stryker.
Treatment:
Device: Gamma Nail 3
PFNA
Active Comparator group
Description:
PFNA Antirotation Synthes
Treatment:
Device: PFNA

Trial contacts and locations

1

Loading...

Data sourced from clinicaltrials.gov

Clinical trials

Find clinical trialsTrials by location
© Copyright 2026 Veeva Systems