Large Diameter Advanta™ V12 Covered Stent Trial for Coarctation of the Aorta

A

Atrium Medical

Status

Completed

Conditions

Coarctation of the Aorta

Treatments

Device: Large Diameter Advanta™ V12 Covered Stent

Study type

Interventional

Funder types

Industry

Identifiers

Details and patient eligibility

About

This study is designed as a prospective, multicenter, non-randomized, single arm study to assess the safety and effectiveness of the Large Diameter Advanta™ V12 Covered Stent for stent implantation in coarctations of the aorta.

Full description

The performance metric for comparison is based on data from the Congenital Cardiovascular Interventional Study Consortium (CCISC) as reported by Golden and Hellenbrand [1]. The CCISC experience from 1989 to 2005 shows a true procedural success rate of 98.6%.

The patient population will be subjects with coarctation of the aorta. A total of 70 subjects, children, adolescents and adults, will be enrolled at up to 15 study sites. Baseline clinical and angiographic assessment will determine the subject's eligibility for enrollment in the study. Subjects will continue in the study for long term annual follow-up through 3, 4, and 5 years.

Enrollment

70 patients

Sex

All

Volunteers

No Healthy Volunteers

Inclusion criteria

  • Patients with a presence of native or recurrent coarctation of the aorta as confirmed by blood pressure gradient, 2D-echocardiography with Doppler or angiography.
  • Subject weighs a minimum of 30 kg.
  • The peak pressure gradient is ≥20 mmHg systolic blood pressure across the coarctation site.
  • Vessels at access site can accept a minimum size of 9 French for a 12 mm balloon and 11 French for a 14 and 16 mm balloon.
  • Coarctation can be successfully crossed with a guide wire, sheath and device.
  • Diameter of transverse arch distal to left subclavian artery is between 9.5 mm and 20 mm in diameter.
  • Subject is able and willing to adhere to all required follow-up visits and testing.
  • Subject is able and willing to adhere to the required follow-up medication regimen.

Exclusion criteria

  • The physician is not able to access the coarctation with standard techniques.
  • Presence of other thoracic aortic arterial lesions or aneurysms requiring treatment within 30 days of the implant procedure.
  • Length of coarctation is greater than 45 mm in length.
  • Connective tissue and genetic disorders, including William, Marfan, Turner, Noonan syndrome.
  • The coarctation has adjacent, acute thrombus.
  • The coarctation was previously treated with a stent.
  • Proximity of the coarctation to an important side branch resulting in crossing of the side branch with the Large Diameter Advanta™ V12 Covered Stent device (e.g. "jailing" of the branch vessel).
  • Subject has a tubular graft, interposition graft, stent graft at or near the coarctation site that would be interfere with delivery, positioning, expansion or stabilization of the Large Diameter Advanta™ V12 Covered Stent
  • Subject has contrast agent hypersensitivity that cannot be adequately premedicated, has a hypersensitivity to stainless steel, expanded polytetrafluoroethylene (ePTFE) or has intolerance to antiplatelet, anticoagulant, or thrombolytic medications.
  • Bloodstream infection
  • Subject is pregnant or breastfeeding.
  • Subject has a co-morbid illness that may result in a life expectancy of less than 1 year.
  • The investigator deems the subject to be an inappropriate candidate for the study.
  • Subject is participating in an investigational study of a new drug, biologic or device at the time of study screening. NOTE: Subjects who are participating in the long term follow-up phase of a previously investigational and now approved product are not excluded by this criterion.

Trial design

Primary purpose

Treatment

Allocation

N/A

Interventional model

Single Group Assignment

Masking

None (Open label)

70 participants in 1 patient group

Investigational Group
Experimental group
Description:
Use of Large Diameter Advanta™ V12 Covered Stent.
Treatment:
Device: Large Diameter Advanta™ V12 Covered Stent