Laser in situ keratomileusis (LASIK) is a widely used procedure for the correction of myopia and myopic astigmatism. Despite its high effectiveness and the general safety of the procedure, long-term safety and effectiveness remain a key concern in ophthalmology. A promising further development is the combination of LASIK with corneal UV-riboflavin crosslinking, which promises additional stability of the cornea.1 This study aims to evaluate the long-term safety and effectiveness of this combined method in comparison to classic LASIK. By analysing long-term results, the aim is to gain well-founded insights that will help to optimise the decision on the most suitable procedure for correcting myopia and myopic astigmatism and to ensure the best possible clinical results for patients.
Full description
The null hypothesis is that combined laser in situ keratomileusis (LASIK) with corneal UV-riboflavin crosslinking (LASIK-Xtra) has the same long-term safety and effectiveness as classic LASIK for the correction of myopia and myopic astigmatism.
Aim of the study The main objective of this study is to determine whether LASIK-Xtra compared to classic femto-LASIK
In addition, possible long-term side effects of the procedures are documented.
The new ophthalmological examination is intended to show that the combination of LASIK-Xtra is at least equally safe and effective compared to the standard variant of Femto-LASIK even after several years.
Safety endpoints:
For the entire study:
study design
The retrospective-prospective study includes:
Performance of non-invasive examinations to assess long-term safety and effectiveness
De-personalised data collection via MS Excel for Mac (Version 16.53, Microsoft, USA)
Statistical analysis using SPSS Statistic 29 software (IBM, USA)
Data security: Data storage is pseudonymised and password-protected
material & methods
Retrospective part:
As part of the study, available visual acuity, results of surgery and examination results already available in the study files of patients who have undergone surgery as part of the NCT 03913338 study will be collected.
No measures will be collected other than those already available in the patient file at the study centre.
Prospective part:
Patients who fulfil the eligibility criteria and agree to participate in the prospective study will be asked to come to the clinic for a single study visit to perform a standard ophthalmological examination in ophthalmology. These include:
Slit lamp examination:
During the study visit, a slit lamp examination will be performed. Particular attention is paid to the cornea. The clarity and quality of the epithelium and stroma will be assessed. All results, including any changes, must be recorded in the patient file and CRF. Photographic documentation is taken.
Subjective refraction:
Basically, subjective refraction is based on the patient's response to changes in lens power and their orientation in relation to the legibility of certain vision charts. This method requires the patient's concentration and co-operation and must be performed by either an optician or ophthalmologist.
Pentacam® AXL Wave (Oculus, Wetzlar, Germany):
This tool is one of the latest ophthalmological measurement devices. The measuring principle is based on a combination of slit illumination and Scheimpflug camera. During data acquisition, the sensors rotate around the eye. It combines the following functions: Scheimpflug tomography, wavefront measurement of the entire eye, objective refraction, axial globe length measurement and retroillumination. All data is collected in one scan within the same measurement axis.
iTrace (Tracey Technologies, Texas, USA): This ray tracing based diagnostic tool offer two different functions: Wavefront measurement and corneal topography. The built-in processor unit allows iTrace (Tracey Technologies, Texas, USA) to calculate additional data (e.g. differentiation between internal optics and total aberration).
Corvis ST® (Oculus, Wetzlar, Germany):
This instrument is a non-contact tonometer that analyses the cornea's response to an air pressure pulse using an ultra-high-speed Scheimpflug camera. The recorded image sequences are used to estimate the intraocular pressure and deformation parameters. All measurements with the Corvis ST are performed in a seated position with the pupil undilated.
Nidek CEM-530 (Nidek Co, Gamagori, Japan):
This is a non-contact spectral microscope for measuring the number and evaluating the shape of the corneal endothelium. Due to the non-contact measurement, there is no risk of corneal infection and no anaesthesia is required.
The measurements are performed by trained and certified staff of the study centre of the Department of Ophthalmology of the Goethe University Hospital.
Patient recruitment:
The patients who successfully participated in the study entitled 'Controlled evaluation of the safety and effectiveness of laser in situ keratomileusis (LASIK) for the correction of myopia and myopic astigmatism in combination with corneal UV riboflavin crosslinking with the KXL system and VibeX Xtra riboflavin eye drops compared to classic LASIK. ' successfully participated in the study period from 2014 to 2018 at the Department of Ophthalmology at Goethe University Frankfurt (clinicaltrials.gov, registration number: NCT 03913338) will be informed about the current study by telephone or electronically via e-mail by employees of the study centre. This involves 19 patients. After giving their consent, they will be invited to the Department of Ophthalmology on an agreed date. This is based on the contact details stored in the study files.
All individuals will be appropriately informed and explicitly informed about the voluntary nature of their participation. Further information can be found in the document 'Patient information and consent form'.
The parameters of the measurements taken during the initial study will be collected from the study file.
6 Data collection The collection of personal patient data is carried out in compliance with the Data Protection Act. The data subject is recorded exclusively via a numerical ID.
statistics The analysis is carried out with SPSS Statistic 29 (IBM, USA). The Shapiro-Wilk test is used to test the normal distribution. The Wilcoxon rank sum test (non-parametric) and the paired t-test (parametric data) are used to determine differences between the different time points. A descriptive data analysis is also carried out.
Case number calculation:
Since the study results are purely descriptive in nature, the sample size is based on the total number of subjects who successfully participated in the study. We expect to collect data from a total of 19 patients (38 eyes) from previous surgeries with LASIK Xtra on one eye and conventional Femto-LASIK on the fellow eye.
Inclusion and exclusion criteria:
Inclusion criteria
For both the retrospective and prospective part of the study:
Exclusion criteria
Applies only to patients participating in the prospective part of the study:
Enrollment
Sex
Ages
Volunteers
Inclusion criteria
For both the retrospective and prospective part of the study:
Exclusion criteria
Applies only to patients participating in the prospective part of the study:
12 participants in 1 patient group
Loading...
Data sourced from clinicaltrials.gov
Clinical trials
Research sites
Resources
Legal