The purpose of this study is to evaluate the feasibility of non-intrusive 24 hours non-invasive measurements with minimized LAVIMO sensor system. The LAVIMO-system is a photoplethysmographic device for reflective mode measurements of the optical damping upper skin layers inside of the ear canal at two different wave lengths. It consists of the in-ear sensor, the electronics and a PC. Vital signs parameter like heart rate, heart rate variability, breathing and arterial blood oxygenation are monitored in patients with sleep apnoea and compared to measurements of standard polysomnography of these patients during one night in the sleep laboratory.
Full description
In 20 patients who routinely have to undergo a polysomnographic night in sleep laboratory LAVIMO measurements like heart rate, heart rate variability, breathing and arterial blood oxygenation are performed parallel to standard polysomnography measurements and subsequently compared to the data of the standard polysomnography. The LAVIMO sensor system consists of the in- ear sensor, the electronics and a PC; the individually formed sensor is embedded into an ear mould for proper fit inside the ear canal. Inside two LEDs emit light into the adjacent skin at 760 and 905 nm wavelengths. The intensity of the backscattered light is detected by a photo detector. In the electronics, the control signals for the LEDs are provided, as well as the photo detector signal is further processed and A-D converted. The electronics also provide a wireless connection to the PC via bluetooth. Data recording, post processing and displaying are tasks of the PC. The feasibility of non- intrusive 24 hours and non-invasive measurements like heart rate, heart rate variability, breathing and oxygen saturation is proved via this minimized sensor and electronics placed at a suitable place at the body guaranteeing high wearing comfort. This includes a wireless data communication for unrestricted mobility. Subsequently the data are compared to the standard polysomnography data to extract vital signs or for example to recognize possible phases of sleep apnoea. The goal in future refering to preventive medical monitoring will be early detection of risk factors for patient's health and improvement of living conditions.
Enrollment
Sex
Ages
Volunteers
Inclusion criteria
Exclusion criteria
Primary purpose
Allocation
Interventional model
Masking
8 participants in 1 patient group
Loading...
Data sourced from clinicaltrials.gov
Clinical trials
Research sites
Resources
Legal