ClinicalTrials.Veeva

Menu

Low-field Thoracic Magnetic Stimulation Increases Peripheral Oxygen Saturation Levels in COVID-19 Patients

E

Elias Manjarrez

Status

Unknown

Conditions

COVID-19
Oxygen Deficiency
Acute Respiratory Failure

Treatments

Device: Low-field thoracic magnetic stimulation (LF-ThMS)

Study type

Interventional

Funder types

Other

Identifiers

NCT04895267
Registration number: 818

Details and patient eligibility

About

This study aimed to present a proof-of-concept that a 30 minutes single-session of low-field thoracic magnetic stimulation (LF-ThMS) on the dorsal thorax can be employed to increase oxygen saturation (SpO2) levels in coronavirus disease (COVID-19) participants significantly. The investigators (Saul M. Dominguez-Nicolas and Elias Manjarrez) hypothesized that the variables associated with LF-ThMS, as hyperthermia, frequency, and magnetic flux density in the dorsal thorax, might be correlated to SpO2 levels in these participants. The investigators designed a single-blind, sham-controlled, crossover study on COVID-19 participants who underwent two sessions of the study (real and sham LF-ThMS), and other COVID-19 participants who underwent only the real LF-ThMS.

Full description

The severe acute respiratory syndrome coronavirus (CoV)-2 (SARS-CoV-2) may cause low SpO2 and respiratory failure in COVID-19 patients. Hence the increase of SpO2 levels could be crucial for the quality of life and recovery of these patients. In this clinical trial, the investigators (Saul M. Dominguez-Nicolas and Elias Manjarrez) propose that an electromagnetic device termed low-field thoracic magnetic stimulation (LF-ThMS) system could be employed for 30 minutes to increase SpO2 levels in COVID-19 participants. This device non-invasively delivers a pulsed magnetic field from 100 to 118 Hz and 10.5 to 13.1 milliTesla (mT) (i.e., 105 to 131 Gauss) to the dorsal thorax. In line with preliminary studies, the scientific literature, and other devices currently used in musculoskeletal magnetic therapy, these frequencies and magnetic flux densities are safe for the participants. The investigators designed a single-blind, sham-controlled, crossover study on COVID-19 participants who underwent two sessions of the study (real and sham LF-ThMS) and other participants who underwent only the real LF-ThMS. The study design includes a 30 minutes single-session of LF-ThMS to avoid confounding factors related to the spontaneous recovery by natural immunity, common in many COVID-19 patients several days after the contagion. Here the LF-ThMS protocol is not intended to demonstrate its use as therapy but is instead designed to examine the following physiological hypothesis. The hypothesis that there is a statistically significant correlation between magnetic flux density, frequency, or temperature associated with the real LF-ThMS and SpO2 levels in COVID-19 participants. In this context, the present clinical trial is relevant because it could motivate future randomized clinical trials to examine whether the LF-ThMS could be helpful as a potential therapy.

Enrollment

17 estimated patients

Sex

All

Ages

20 to 85 years old

Volunteers

No Healthy Volunteers

Inclusion criteria

  • Adult participants diagnosed with mild to moderate COVID-19 disease without pneumonia.
  • COVID-19 participants with a SpO2 level less or equal to 90 %, exhibiting difficulty breathing, but not intubated.
  • COVID-19 participants with similar pharmacological treatment against COVID-19.
  • 20-85 years old

Exclusion criteria

  • COVID-19 patients with acute respiratory failure requiring urgent intubation
  • COVID-19 patients with impaired consciousness
  • Pregnant woman
  • Patients with metallic implants in the thorax, abdomen, or arms, or with electronic medical devices such as pacemakers
  • Children

Trial design

Primary purpose

Basic Science

Allocation

Non-Randomized

Interventional model

Crossover Assignment

Masking

Double Blind

17 participants in 2 patient groups

Real Low-field thoracic magnetic stimulation (LF-ThMS)
Experimental group
Description:
Crossover, single-blind session of low field thoracic magnetic stimulation (real LF-ThMS)
Treatment:
Device: Low-field thoracic magnetic stimulation (LF-ThMS)
Sham Low-field thoracic magnetic stimulation (LF-ThMS)
Sham Comparator group
Description:
In the same patients the coils are positioned in the same coordinates for sham exposure, but the pulse generator is not turned on. Subjects are blinded for the real LF-ThMS or sham stimulation conditions.
Treatment:
Device: Low-field thoracic magnetic stimulation (LF-ThMS)

Trial contacts and locations

1

Loading...

Data sourced from clinicaltrials.gov

Clinical trials

Find clinical trialsTrials by location
© Copyright 2026 Veeva Systems