ClinicalTrials.Veeva

Menu

Low Fresh Gas Flow in Prone Position

P

Prof. Dr. Cemil Tascıoglu Education and Research Hospital Organization

Status

Completed

Conditions

Anesthesia

Treatments

Procedure: Normal Fresh Gas Flow in Prone Position
Procedure: Low Fresh Gas Flow in Prone Position

Study type

Interventional

Funder types

Other

Identifiers

NCT05462327
48670771-514.10/1477

Details and patient eligibility

About

Low flow anesthesia in the prone position was safe in terms of systemic hemodynamics and did not reduce cerebral oxygenation compared to normal flow.

Full description

Patients were randomly allocated to either low fresh gas flow(LF, 0,5 L/min during maintenance) or normal flow (NF, 2 L/min)) general anesthesia. In both groups, participants were first administered with 100% oxygen at a 4 L/min flow rate. Propofol 2-2,5 mg/kg, rocuronium bromide 0,6 mg/kg, and fentanyl 1 mcg/kg IV were used for anesthesia induction.In the operating room, pulse rate, mean arterial pressure (MAP), peripheral hemoglobin oxygen saturation (spO2), and right and left side regional cerebral oxygen saturation (Masimo's O3 regional oximetry device) were measured before premedication and anesthesia induction, at 10 minutes after endotracheal intubation, at 10 minutes after prone positioning, at 1st, 2nd, 3rd, 4th and 5th hours of operation, before repositioning to supine, after the resumption of supine position and at 5 minutes after extubation. In conclusion, low flow anesthesia in patients undergoing surgery in the prone position did not cause a reduction in cerebral oxygenation compared to normal flow.

Enrollment

46 patients

Sex

All

Ages

18+ years old

Volunteers

Accepts Healthy Volunteers

Inclusion criteria

  • undergoing surgery in the prone position
  • having an American Society of Anesthesiologists (ASA) physical status I to III
  • willingness to participate in the study

Exclusion criteria

  • having a Glasgow coma scale (GSC) score ≤ 12
  • previous history of cranial surgery
  • advanced cardiovascular and/or pulmonary disease
  • mental retardation
  • neurological disease

Trial design

Primary purpose

Screening

Allocation

Randomized

Interventional model

Parallel Assignment

Masking

None (Open label)

46 participants in 2 patient groups

Low Fresh Gas Flow in Prone Position
Experimental group
Description:
Low fresh gas flow (0,5 L/min during maintenance)
Treatment:
Procedure: Low Fresh Gas Flow in Prone Position
Normal Fresh Gas Flow in Prone Position
Active Comparator group
Description:
Normal flow (2 L/min) in general anesthesia.
Treatment:
Procedure: Normal Fresh Gas Flow in Prone Position