Lung Ultrasound in Neonatal Intensive Care Units

A

Assiut University

Status

Not yet enrolling

Conditions

Neonatal Respiratory Distress

Treatments

Device: Ultrasound

Study type

Observational

Funder types

Other

Identifiers

NCT06372951
Lung ultrasound in neonate

Details and patient eligibility

About

Identification of lung diseases causing neonatal respiratory distress by lung ultrasound as a tool that can replace x-ray .

Full description

  • Lung disease is the most common cause of neonatal respiratory distress.

  • It can result in respiratory failure and death in severe cases.

  • The mortality rate is approximately 11%:32%.

  • Identification of the etiology of lung disease is important for neonatologists.

  • Traditionally, chest X-ray has been considered as the most valuable imaging modality for the diagnosis of lung diseases, but it unavoidably causes radiation damage to the patient.

  • Neonates are susceptible to radiation because they have rapidly dividing cells that cannot repair mutated DNA.

  • The risk of cancer induction in infants receiving a single small dose of radiation is 2-3 times higher than the average population and 6-9 times higher than the risk from an exposure of a 60-year-old patient.

  • New imaging modalities have been introduced in clinical practice in recent years such as lung ultrasound.

  • One of the most common causes of neonatal respiratory distress that can be diagnosed by ultrasound is :Respiratory Distress Syndrome:

    • Respiratory distress syndrome.. is a major cause of neonatal mortality.
    • It mainly occur in preterm infants due to structural and functional lung immaturity.
    • Pulmonary surfactant insufficiency is an important pathogenesis in respiratory distress syndrome.
    • The ultrasonic features of respiratory distress syndrome are: Compact B-Lines, white lung appearance, abnormality in pleural line (thick and irregular),lung consolidation.
  • Lung ultrasound has the advantages of :

    • Non-ionizing.
    • Easy to operate.
    • Low coast.
    • Portable for bedside use.
    • The imaging is performed in real-time.
  • Thus making it as a potential tool to be used in neonatal intensive care units.

Enrollment

132 estimated patients

Sex

All

Ages

1 to 28 days old

Volunteers

No Healthy Volunteers

Inclusion criteria

  • Neonates in neonatal intensive care units

Exclusion criteria

  • Patients with poor-quality of lung ultrasound image.