ClinicalTrials.Veeva

Menu

Magnetic Resonance Imaging (MRI) Sequences Optimization in Healthy Subjects (OSS-IRM)

R

Rennes University Hospital

Status

Completed

Conditions

Healthy Volunteers

Treatments

Device: Magnetic Resonance Imaging

Study type

Interventional

Funder types

Other

Identifiers

NCT02900339
2011-A01531-40 (Other Identifier)
35RC11_8965

Details and patient eligibility

About

Magnetic resonance imaging (MRI) is a noninvasive and non-ionizing (no use of X-rays) imaging modality. Today it is considered an anatomical and functional exploration reference technique. Since its inception around 1985, this technology is constantly evolving.

Many advances in MRI require constant adaptations of radiological practices. The morphological image is now associated with functional and parametric information (infusion, diffusion spectroscopy, etc ...). In parallel, work combining acquisition and post-processing of data also open new applications (tractography, functional MRI, etc ....). Thus, more and more procedures are necessary to "integrate" these techniques for the diagnosis and adapt to new demands of clinicians.

The type of sequence and its associated parameters allow to directly influence the contrast of images, to characterize tissue compared to another and, ultimately, to highlight morphological or functional abnormality. Image quality can be optimized on each MRI, depending on the time available for the acquisition on the one hand, and on the desired resolution and contrast, on the other hand. For each sequence, it is therefore necessary to find a compromise that will optimize the diagnostic quality of the examination.

This optimization requires a phase focusing on healthy volunteers. It is therefore important that researchers and physicists could design on healthy volunteers, the best settings of all parameters for an image or spectrum. Indeed, it is always necessary to properly optimize every parameter choices before beginning a study of a cohort of patients.

In this context, the main objective of this study is to optimize sequences and imaging protocols to evaluate and validate the choice of parameters in healthy volunteers.

Enrollment

628 patients

Sex

All

Ages

18+ years old

Volunteers

Accepts Healthy Volunteers

Inclusion criteria

  • Men or women aged over 18 years
  • Written informed consent given

Exclusion criteria

  • contraindication to MRI :

    • Claustrophobia
    • morphotype not allowing access to MRI
    • Wear a metallic implant, such as:
    • Pacemaker (pacemaker)
    • Ferromagnetic surgical clips
    • Intra orbital metallic foreign bodies or encephalic
  • Pregnancy

  • Breastfeeding

  • Adults under guardianship, trusteeship or safeguard justice

  • No social Insurance

Trial design

Primary purpose

Diagnostic

Allocation

N/A

Interventional model

Single Group Assignment

Masking

None (Open label)

628 participants in 1 patient group

MR parameters optimization
Experimental group
Description:
The study will be conducted on the MRI of the Neurinfo platform, in the radiology department of the University Hospital of Rennes.
Treatment:
Device: Magnetic Resonance Imaging

Trial contacts and locations

1

Loading...

Data sourced from clinicaltrials.gov

Clinical trials

Find clinical trialsTrials by location