ClinicalTrials.Veeva

Menu

Microplasty Tibial Tray Data Collection (MTT)

Zimmer Biomet logo

Zimmer Biomet

Status

Withdrawn

Conditions

Joint Disease

Study type

Observational

Funder types

Industry

Identifiers

Details and patient eligibility

About

The purpose of this prospective clinical data-collection is to document the performance and clinical outcomes of the Microplasty Tibial Tray.

Full description

FDA has cleared this device via premarket notification 510(k) K063732. By being CE Marked, the Microplasty Tibial Tray also conforms to the essential requirements of EC Directive 93/42/EEC; in accordance to 13485:2003. The data gathered would be collated and used to provide feedback to design engineers, support marketing efforts, and answer potential questions from reimbursement agencies, and will serve as a part of Biomet's Post Market Surveillance System.

Inclusion/exclusion criteria are identical to those indications and contraindications stated in the FDA approved labeling for the device in 510(k) K063732 Surgical techniques and patient care are to be standard for the surgeon participating in the protocol and should be maintained the same throughout the course of the data-collection. There will be no experimental or investigational devices used. There will be no experimental or investigational surgical techniques used. The devices and products will be used in accordance with their instructions for use and/or approved labeling. Any use of the device or collection of clinical data outside of the United States should comply with all local, state, and/or national and international regulations.

Function will be assessed through the Knee Society Score . Survivorship will be documented by asking the surgeon to document revisions and complications.

Sex

All

Ages

18+ years old

Volunteers

No Healthy Volunteers

Inclusion criteria

The inclusion criteria will be identical to the indications stated in the FDA approved labeling for the device in 510(k) K063732. These indications are stated below:

  • Painful and disabled knee joint resulting from osteoarthritis, rheumatoid arthritis, traumatic arthritis where one or more compartments are involved.
  • Correction of varus, valgus, or posttraumatic deformity.
  • Correction or revision of unsuccessful osteotomy, arthrodesis, or failure of previous joint replacement procedure.

Patient selection factors to be considered include:

  • Need to obtain pain relief and improve function
  • Ability and willingness of the patient to follow instructions, including control of weight and activity level
  • A good nutritional state of the patient, and
  • The patient must have reached full skeletal maturity

Non-coated (Interlock®) devices are indicated for cemented application only.

Exclusion criteria

The exclusion criteria will be identical to the contraindications stated in the FDA approved labeling for the device in 510(k) K063732. These contraindications are stated below:

Absolute contraindications include: infection, sepsis, and osteomyelitis.

Relative contraindications include:

  • Uncooperative patient or patient with neurologic disorders who are incapable of following directions,
  • Osteoporosis,
  • Metabolic disorders which may impair bone formation,
  • Osteomalacia,
  • Distant foci of infections which may spread to the implant site,
  • Rapid joint destruction, marked bone loss or bone resorption apparent on roentgenogram,
  • Vascular insufficiency, muscular atrophy, neuromuscular disease,
  • Incomplete or deficient soft tissue surrounding the knee.

Biomet Microplasty™ Tibial Trays are contraindicated for use with constrained bearings.

Trial design

0 participants in 1 patient group

510(k) Inclusion Criteria
Description:
Any person meeting the inclusion criteria for the device may be included in this study. These patients tend to be those seeking relief from painful or debilitating knee joint disease.