Aim: This study was conducted to determine the effect of a mobile education program and telephone monitoring developed for patients with implantable cardioverter defibrillators (ICD) on shock anxiety, device acceptance, and self-efficacy.
Method: The study was designed as a single-blind, randomized controlled trial consisting of two phases. In the first phase, the Mobile ICD Education Program (M-ICDEP) was developed. In the second phase, the effectiveness of M-ICDEP was evaluated through a randomized controlled design with 88 ICD patients who attended routine battery check-ups.
Research data were collected through the mobile education program using the Personal Information Form, Florida Shock Anxiety Scale (FSAS), Florida Patient Acceptance Scale (FPAS), and the Self-Efficacy and Outcome Expectations Scales After ICD Implantation (OE-ICD and SB-ICD). Additionally, patients underwent a shock management simulation via M-ICDEP, and their data were assessed using the Shock Management Control Form, which was included in the evaluation of shock anxiety.
Patients in both the intervention and control groups used M-ICDEP for three months. The control group had access only to the brief educational booklet section containing general information, while the intervention group had access to all sections. Patients in the intervention group also received telephone follow-ups during the second, fifth, and eighth weeks of the monitoring period. Data were collected twice: once before the intervention (pre-test) and once in the third month (post-test). Statistical analyses will conducted using the SAS 9.4 software package.
Full description
Definition and Importance of the Problem
Implantable cardioverter defibrillators (ICDs) are devices developed to prevent sudden cardiac death resulting from ventricular arrhythmias. According to the 2017 guidelines of the European Heart Rhythm Association, the annual number of ICD implantations per million people is reported to be 107 worldwide and 115 in Turkey. Furthermore, over the past decade, implantation rates have increased by 44% globally and 804.1% in Turkey. Although ICD therapy has been proven to reduce mortality by 28-40% and is more effective than antiarrhythmic drugs, living with an ICD can lead to various psychosocial problems in patients. In particular, anxiety and device adaptation problems are frequently encountered after implantation.
The foreign nature of the ICD, concerns about living dependently on the device, its activation during potentially fatal arrhythmias, and its capability to deliver shocks contribute to increased anxiety. Studies indicate that 44-55% of patients experience shock-related anxiety, with uncertainty regarding the sensation, location, and timing of shocks exacerbating this distress. Additionally, 95% of individuals who have experienced a shock develop anxiety. Anxiety and shock experiences can hinder device acceptance, adversely affecting patients' daily lives. It has been reported that individuals struggling with device acceptance exhibit lower levels of self-efficacy and that self-efficacy plays a crucial psychological role in disease adaptation. Consequently, assessing patients' self-efficacy is of significant importance.
Adequate patient education, telephone follow-ups, and continuous care have been shown to enhance device acceptance and self-efficacy. Despite the recognized importance of patient education and follow-up, 97% of ICD patients report needing further education and monitoring, suggesting a gap in the provision of necessary training.
Currently, innovative and interactive educational methods, such as mobile health applications and simulation techniques, are widely used for patient education. Mobile applications facilitate easy access to information, while simulation methods provide a realistic learning environment by allowing patients to experience real-life scenarios. While international literature includes studies on the use of mobile health applications for ICD patient monitoring, no studies have been identified that apply a mobile education program. Therefore, this study is expected to contribute innovatively to the literature by providing a realistic learning environment through a mobile education program incorporating different algorithms and a shock management simulation. Additionally, it is hypothesized that mobile education programs and telephone monitoring may improve patients' shock anxiety, device acceptance, and self-efficacy levels.
Aim of the Study
This study aims to determine the effect of a mobile education program and telephone monitoring developed for ICD patients on shock anxiety, device acceptance, and self-efficacy. It has been designed as a single-blind, randomized controlled trial consisting of two phases. The first phase involves the development of the mobile education program, while the second phase aims to evaluate the impact of the program on patients' shock anxiety, device acceptance, and self-efficacy.
The research hypotheses are formulated as follows:
Compared to the control group, ICD patients in the intervention group who receive the mobile education program and telephone monitoring will experience:
Enrollment
Sex
Ages
Volunteers
Inclusion criteria
Exclusion criteria
Primary purpose
Allocation
Interventional model
Masking
88 participants in 2 patient groups
Loading...