ClinicalTrials.Veeva

Menu

Modified Deep Extubation vs. Standard Awake Extubation (mDE)

S

Samuel Lunenfeld Research Institute, Mount Sinai Hospital

Status

Enrolling

Conditions

Extubation

Treatments

Procedure: standard awake extubation
Procedure: modified deep extubation (mDE)

Study type

Interventional

Funder types

Other

Identifiers

NCT06318715
23-0009-A

Details and patient eligibility

About

The proposed study is to compare a modified DE technique, which is regularly used for low-risk patients by staff anesthesiologists at our institution, to a standard awake extubation. This modified deep extubation (mDE) occurs while the patient is still anaesthetized but at a lower dose of anaesthetic gas than previously described, and balanced with long acting opioids to attenuate the airway reaction. As previously stated, the literature shows that the risks of DE are equivalent to those of regular AE practice. Our hypothesis is that mDE will shorten the time from the end of the surgery (completion of last stitch) to the moment the patient is ready to leave the OR by at least 5 minutes when compared to standard AE practice.

Full description

Study type Randomized Controlled Trial comparing two extubation strategies for low-risk airway elective patients undergoing general anesthesia.

Population

  • Inclusion criteria ASA I-III patients, scheduled for laparoscopic surgery under general anesthesia.

  • Exclusion criteria

    • High-risk patients

      • Documented difficult airway during intubation or developed intraoperatively.
      • Full stomach
      • Pregnant women
      • Emergency surgery
      • BMI>30
      • Intraoperative bleeding leading to transfusion
    • Use of remifentanil during extubation

    • Requirement for prone position for surgical approach (i.e., spine surgery, anal fistulectomy, tumor resection of the back, etc)

    • Absolute indication for awake or deep extubation

    • Use of opioids in chronic pain patients

Procedures Patients that are potential candidates for the study will be selected according to inclusion and exclusion criteria when they undergo assessment on the Pre-Admission Unit (PAU). They will be selected from the PAU assessment list the day before the appointment by the research assistant. For both in person and phone interviews, the PAU personnel (nurse or anesthesiologist) will briefly introduce the patient to the study, and if the patient is interested in participating, the research assistant will approach them with detailed information and a hard-copy leaflet (or an email copy for a phone interview, if the patient agrees) regarding the study.

Informed consent to participate in the study will be taken by the research assistant on the day of surgery during the anesthesia assessment in the preoperative area. Patients will be randomized to either the AE or mDE group. Randomization will be performed in advance, using a computer-generated program and the participant assigned number. The patient and the research assistant will be blinded to the study group allocation. A study investigator, who will know the allocation of the patient, will assign the patient to the anesthesiologists that will provide the anesthesia and perform the extubation process according to group allocation. The anesthesiologists that are part of the research team will perform the extubation in the mDE group, and other attending anesthesiologists will perform their standard awake extubation in the AE group.

In the AE group, the attending anesthesiologist will perform the extubation according to the standard practice as follows:

  1. Sevoflurane (anesthetic gas) will be reduced and the ventilator will be set up to wean patients from mechanical support using the anesthesiologist's method of preference.
  2. Long-acting opioid (morphine or hydromorphone) will be given as per their clinical judgement.
  3. Reversal of neuromuscular block will be performed in all patients and confirmed by a nerve stimulator Train of Four (TOF) ratio of > 0.9, which is the standard practice in patients receiving muscle relaxants as per the last clinical guidelines.
  4. Oral suctioning will be performed.
  5. Patients will be extubated once they are able to obey a verbal command of "open your eyes".
  6. If needed, relief of airway obstruction will be performed at the discretion of the attending anesthesiologist using means such as an oral airway, or a jaw-thrust maneuver.

In the mED group, the attending anaesthesiologist who is familiar with the mDE technique will use the following protocol:

  1. Towards the end of the surgery, sevoflurane will be set at an end-tidal concentration (ET%) of 0.7 MAC, the ventilator will be set to pressure support mode, and the patient will be allowed to breathe spontaneously.
  2. A low dose of long-acting opioid (morphine 0.05 mg/kg or hydromorphone 0.01 mg/kg) will be given before the end of the surgery, according to the anesthesiologist's criteria.
  3. Reversal of neuromuscular block will be performed in all patients and confirmed by a nerve stimulator TOF ratio of > 0.9, which is the standard practice in patients receiving muscle relaxants as per the last clinical guidelines).17
  4. Oral suctioning will be performed while the patient is on Sevoflurane 0.7 MAC. The use of oral airway to avoid airway obstruction will be at the anesthesiologist discretion.
  5. Ventilation support will be changed to the spontaneous mode after confirming an adequate respiratory drive on pressure support mode. Sevoflurane will then be stopped at the time of the last surgical stitch, and the fresh gas flow (FGF) with FiO2 1.0 will be adjusted at 18 litres/minute to optimize gas washout.
  6. The patient will be extubated on spontaneous ventilation as soon as the ET% of sevoflurane drops to 0.4 MAC, once they achieve a minimum tidal volume of more than 3 millilitres per kilogram of ideal body weight and a respiratory rate of 8-12 breaths per minute, while they are still anesthetized under the effect of sevoflurane.
  7. If needed, relief of airway obstruction will be performed at the discretion of the attending anesthesiologist by using means such as an oral airway, or a jaw-thrust maneuver.

During the patient care, the research assistant will record the events and times correlating to the primary and secondary outcomes by direct observation of the extubation process. The patient will also be interviewed by the research assistant in PACU regarding their experience with the recovery process once they are fully awake and ready to be transferred to the ward or discharged home. The patient will be blind to the allocation of the study group until the end of interview. If any problems occur during the extubation process, the patient will be debriefed by the attending anesthesiologist as regularly done in these cases regardless of study participation.

In case the patient was considered as a difficult intubation at the beginning of the case, or that the patient develops respiratory or hemodynamic instability, they would be excluded from the study and the extubation process will be carried out according to the attending anesthesiologist's clinical judgment.

Enrollment

60 estimated patients

Sex

All

Volunteers

No Healthy Volunteers

Inclusion criteria

  • ASA I-III
  • laparoscopic surgery under general anesthesia

Exclusion criteria

  • High-risk patients:

    • Documented difficult airway during intubation or developed intraoperatively.
    • Full stomach
    • Pregnant women
    • Emergency surgery
    • BMI>30
    • Intraoperative bleeding leading to transfusion
  • Use of remifentanil during extubation

  • Requirement for prone position for surgical approach (i.e., spine surgery, anal fistulectomy, tumor resection of the back, etc)

  • Absolute indication for awake or deep extubation

  • Use of opioids in chronic pain patients

Trial design

Primary purpose

Treatment

Allocation

Randomized

Interventional model

Parallel Assignment

Masking

Single Blind

60 participants in 2 patient groups

modified deep extubation
Experimental group
Description:
This modified deep extubation (mDE) occurs while the patient is still anaesthetized but at a lower dose of anaesthetic gas than previously described, and balanced with long acting opioids to attenuate the airway reaction.
Treatment:
Procedure: modified deep extubation (mDE)
standard awake extubation
Experimental group
Description:
awake extubation (AE) is still considered the standard practice.
Treatment:
Procedure: standard awake extubation

Trial contacts and locations

1

Loading...

Central trial contact

naveed siddiqui, MD

Data sourced from clinicaltrials.gov

Clinical trials

Find clinical trialsTrials by location
© Copyright 2025 Veeva Systems