ClinicalTrials.Veeva

Menu

Multi-center Study On the Treatment and Prognosis of Arteriosclerosis Obliterans With Different Caliber Balloon

J

Jun-min Bao

Status

Unknown

Conditions

Arteriosclerosis; Extremities

Treatments

Device: matched caliber balloon
Device: Increased caliber balloon

Study type

Interventional

Funder types

NETWORK

Identifiers

NCT03725683
JUn-min Bao

Details and patient eligibility

About

In the endoscopic treatment of superficial femoral artery and/or proximal popliteal artery in patients with lower extremity arteriosclerosis occlusion, the intercalation caused by the predilation of increasing caliber balloon and matching caliber balloon was compared, and then the impact of the two predilation methods on the intraoperative treatment strategy and short and medium-term prognosis was analyzed. The study was designed as a prospective, multi-center, single-blind, randomized, controlled study. It is planned to set up 5-10 research centers with 340 subjects, and the single center will be less than or equal to 100 subjects, in the form of competition from each research center.

Enrollment

340 estimated patients

Sex

All

Ages

40 to 85 years old

Volunteers

No Healthy Volunteers

Inclusion criteria

  1. Target lesions from superficial femoral artery to popliteal artery P1 segment; Proximal anatomical markers of target lesions:

    1. 1cm below the fork of the common femoral artery;
    2. Distal anatomical sign of target lesions: upper border of patella;
  2. Target lesions may be single, combined, or tandem primary lesions of stenosis and/or occlusion, and meet one of the following criteria:

    1. In contrast, The stenosis rate was greater than or equal to 70% and less than 100%, and the total length of the lesions was greater than or equal to 40mm and less than or equal to 200mm.
    2. The total length of the lesion is less than 100mm.
    3. The total length of the lesion is less than or equal to 200mm, and the length of the occlusion segment is less than or equal to 100mm.

    Note: the distance between the lesions is no more than 30mm, and the distance between the lesions is > 30mm. Patients with multiple target lesions judged as 2 or more independent lesions met the inclusion criteria.

  3. The diameter of the reference vessels of target lesions shall be 4mm or more and 7mm or less.

  4. If the subject has ipsilateral iliac or lower knee lesions to be treated, the above lesions shall be successfully treated with target lesions, and the following criteria shall be met:

    1. Residual stricture of the common iliac lesion < 30%;
    2. An upper knee has at least one or more free outflow tract, i.e., residual stenosis < 50%;
    3. No embolism, rupture or other serious adverse events occurred during the operation.
  5. The pregnancy test results of fertile female subjects must be negative and there is no pregnancy plan during the study period;

  6. The patient or client signs the patient's informed consent;

  7. Understand and accept the duration of this study, and be able to cooperate with follow-up and evaluation;

  8. Subject's life expectancy is greater than or equal to 12 months after evaluation by the investigator.

Exclusion criteria

  1. The investigator believes that the subject has the possibility of non-compliance with the follow-up plan;

  2. Patients with cerebral apoplexy or st-segment elevation myocardial infarction in the last 3 months;

  3. Combined with the following diseases

    1. Patients diagnosed with thrombotic occlusive vasculitis;
    2. combined with abdominal aortic aneurysm/thoraco-abdominal aortic aneurysm (with mural thrombus inside the aneurysm cavity);
    3. coagulation defect;
    4. high coagulation status;
  4. blood index

    1. Serum creatinine > 170umol;
    2. White blood cell count < 3.0 x 109/L or > 14.0 x 109/L;
    3. Patients with platelet count < 80 x 109/L or > 500 x 109/L;
  5. Patients who are known to be allergic to anticoagulant, antiplatelet, contrast agent and other drugs; Examples: heparin, clopidogrel, iodixanol, etc.

  6. Target lesions are non-primary lesions of restenosis and anastomotic stenosis within the stent;

  7. Acute or subacute thrombosis of target lesions;

  8. There are aneurysms in the vicinity of target lesions, and the proximity refers to no more than 20mm.

  9. The patient is a lactating woman or a pregnant woman.

Trial design

Primary purpose

Treatment

Allocation

Randomized

Interventional model

Parallel Assignment

Masking

Single Blind

340 participants in 2 patient groups

Incrementing groups
Experimental group
Description:
Each of the Increased caliber balloon capsules was predilated one by one, and the order of the increased balloon capsules was as follows: Balloon 2 diameter = target lesion reference vessel diameter minus 1; Balloon 3 diameter = target lesion reference vessel diameter;
Treatment:
Device: Increased caliber balloon
matching groups
Experimental group
Description:
Pre-dilatation of the matched caliber balloon, whose diameter = the target lesion's diameter as a reference vessel, was applied.
Treatment:
Device: matched caliber balloon

Trial contacts and locations

11

Loading...

Central trial contact

Junmin Bao, Doctor's degree

Data sourced from clinicaltrials.gov

Clinical trials

Find clinical trialsTrials by location
© Copyright 2026 Veeva Systems